<br />10 <br /> <br />Table 2 <br /> <br />MIXED MEDIA TEST METHODS AND U(lVIREMENTS <br /> <br />Waste Removal <br /> <br />Media: 3 artlfldal sponges, 3f4 x 3f4 x 2 Inches <br />3 natural sponges, 2 Inch nominal diameter <br />I latex cylinder, I x 4-3/8 Inches <br />2 non.woven fabrics. 5.1/2 x 6-1f2lnches <br />Total wet mass approximately 232 grams. <br /> <br />l'roetdurt: <br />Place the bulk media In the well. TrIp the flush release device. After completion of the <br />Initial flush, count the media remaining In the well and trap way. Repeat the procedure <br />until five sets of data are obtained. <br /> <br />Per(omumet &quirement: <br />All the media must dear the bowl and trap way on each Initial flush. If all media are not <br />removed on the Initial flush, the test Is reported as a failure. Report results as a percent of <br />tests passed based on the five Initial flushes. <br /> <br />Transport <br /> <br />Media: 3 artlffdal sponges, 3/4 x 3/4 x 21ndJes <br />3 natural sponges, 2 Inch nominal diameter <br />1 latex cylinder, I x 4-3/8 Inches <br />2 non-woven fabrics, 5.1/2 lC 6-1/2 Inches <br />Total wet mass approximately 232 grams <br /> <br />ASPE Research Foundation <br />