Laserfiche WebLink
<br />9 <br /> <br />Table 1 (cont'd) <br /> <br />SANITARY PERFORMANCE TEST METHODS AND REQUIREMENTS <br />ANSI Al12.19.6 (coot'd) <br /> <br />1000. See detailed Instructions In the referenced standard. <br />d) Add concentrated dye solution to the bowl water (1/40 of the measured trap seal <br />volume). Stir the solution In the bowl. TJip the flush release device. <br />e) Extract a water sample from the bowl and compare with known solutions. Clean <br />the bowl to remove traces of dye solution and repeat the procedure untU three sets of <br />dati are obtained. <br /> <br />PerftmnanCtl Rqulremll7lt: <br /> <br />A dilution ratio of at least 100 shall be obtained In each Inltlal flush. <br /> <br />TrlUlSport (ANSI A.112.19.6) <br /> <br />6) Carryout Test - 100 polypropylene balls having a diameter of 3/4 Inch and an <br />average bulk density of 0.85.0.90 grams/an3, <br /> <br />ProCtldu~: <br />Place the 100 balls In the well and flush the product. Observe the distance of travel of <br />each exiting ball. Remove all test media before the next run. <br />Record the location of each ball In one of the eight categories defined In the standard. <br />Calculate the weighted average (number of balls x average a1stance travelled). <br /> <br />p~ Rtqulrement: <br />The average carry distance per ball shall be 40 feet. <br /> <br />Note: Refer to ANSI Standard Al12.19.2 for additional Important details. <br /> <br />ASPE Research Foundation <br />