Laserfiche WebLink
<br />WATER BALANCE <br /> <br />Water uses in this facility can be divided into five major groups; domestic use, facility <br />cooling, kitchen use, washing & sanitation and landscape irrigation, Estimates of water <br />usage in each of these categories are discussed in the following paragraphs, This water <br />balance will attempt to account for water uses both before and after the remodeling of the <br />facility, <br /> <br />Domestic Use - Domestic use is largely restroom usage, All restrooms in the State Services <br />Building have been remodeled, New flush-valve toilets have been installed that utilize 1.6 <br />gallon per flush, replacing older less efficient fixtures, It is assumed that the facility was <br />equipped with 4.5 gallon per flush toilets before remodeling, Lavatory faucet flows were <br />measured at 2,0 gpm, Prior to remodeling, faucet flow rates were assumed to be 3.5 gallons <br />per minute, Urinals were estimated to be 1.5 gpf models, both before and after the <br />renovation, <br /> <br />It was reported that there are now 415 full time employees at the facility, less than the 515 <br />that worked there prior to the remodeling. Employees work Monday through Friday, or 260 <br />days per year, Visitors also do business in this building, It is assumed that 200 visitors per <br />day use the restroom facilities, and that the number of visitors remained the same before <br />and after the renovation to the facility, Estimates of domestic water use, before and after, <br />are listed below, <br /> <br />Before Remodeling <br />* employee toilet <br />* employee lav <br /> <br />515 people x 3 uses/da x 4.5 gal/flush x 260 dalyr == 1,800,000gal. <br />515 people x 1 minlda x 3.5 gpm x 260 dalyr == 469,000 gal, <br /> <br />* visitor toilet 200 people x 1 use/da x 4.5 gal/flush x 260 dalyr == 234,000 gal, <br />* visitor lav 200 people x ,25 minlda x 3,5 gpm x 260 dalyr == 46,000 gal, <br />Total domestic use before renovation == 2.S49.000l!a1. per year <br /> <br />After Remodeling <br />* employee toilet <br />* employee lav <br /> <br />415 people x 3 uses/da x 1,6 gal/flush x 260 dalyr == 518,000 gal, <br />415 people x 1 minlda x 2,0 gpm x 260 dalyr = 216,000 gal, <br /> <br />* visitor toilet 200 people x 1 use/da x 1,6 gal/flush x 260 dalyr == 83,000 gal, <br />* visitor lav 200 people x .25 minlda x 2,0 gpm x 260 dalyr == 26,000 gal, <br />Total domestic use after renovation == 863.000 l!:al. per year <br /> <br />Facility Coolinl!: - A 650 ton cooling tower is located in the State Services Building, This <br />tower provides cooling for this facility and also for other buildings in the State Capitol <br />Complex, The cooling tower remained in use during the renovation of the State Services <br />Building and accounts for most of the water use while the building was unoccupied, It is <br /> <br />3, <br />