Laserfiche WebLink
ACZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334 -5493 <br />Rio Grande Silver, Inc. <br />ACZ ID WORKNUM PARAMETER <br />METHOD QUAL DESCRIPTION <br />REPAD.15 06 05 01 <br />Nickel (1312) <br />Potassium (1312) <br />WG330950 Selenium (1312) <br />WG330840 Silica (1312) <br />WG330950 Silver(1312) <br />WG330840 Sodium (1312) <br />WG330950 Thallium (1312) <br />Uranium (1312) <br />Zinc (1312) <br />WG330759 Chloride (1312 DI) <br />Inorganic Extended <br />Qualifier Report <br />ACZ Project ID: L96798 <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />HD Analysis is outside the intended scope of the method, <br />which does not provide hold time information for soil <br />extracts No hold time is observed for collection to <br />extraction The referenced method hold time is observed <br />for extraction -to- analysis <br />SM4500CI -E M1 Matrix spike recovery was high, the recovery of the <br />associated control sample (LCS or LFB) was acceptable <br />SM4500CI -E RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330799 Fluoride (1312 DI) SM4500F -C RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330670 Nitrate /Nitrite as N (1312 -DI) M353 2 - Automated Cadmium HD Analysis is outside the intended scope of the method, <br />Reduction which does not provide hold time information for soil <br />extracts No hold time is observed for collection to <br />extraction The referenced method hold time is observed <br />for extraction -to- analysis <br />Nitrite as N (1312 -DI) M353 2 - Automated Cadmium HD Analysis is outside the intended scope of the method, <br />Reduction which does not provide hold time information for soil <br />extracts No hold time is observed for collection to <br />extraction The referenced method hold time is observed <br />for extraction -to- analysis <br />M353 2 - Automated Cadmium RA Relative Percent Difference (RPD) was not used for data <br />Reduction validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330656 Nitrogen, ammonia (1312 -DI) M350 1 - Automated Phenate HD Analysis is outside the intended scope of the method, <br />which does not provide hold time information for soil <br />extracts No hold time is observed for collection to <br />extraction The referenced method hold time is observed <br />for extraction -to- analysis <br />M350 1 - Automated Phenate RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330669 Phosphorus, ortho dissolved (1312 -DI) M365 1 - Automated Ascorbic HD Analysis is outside the intended scope of the method, <br />Acid which does not provide hold time information for soil <br />extracts No hold time is observed for collection to <br />extraction The referenced method hold time is observed <br />for extraction -to- analysis <br />M365 1 - Automated Ascorbic RA Relative Percent Difference (RPD) was not used for data <br />Acid validation because the sample concentration is too low for <br />M6010B ICP <br />M6010B ICP <br />M6020 ICP -MS <br />M6010B ICP <br />M6020 ICP -MS <br />M6010B ICP <br />M6020 ICP -MS <br />M6020 ICP -MS <br />M6020 ICP -MS <br />SM4500CI -E <br />Page 26 of 39 <br />