ACZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334 -5493 <br />Rio Grande Silver, Inc. <br />ACZ ID WORKNUM PARAMETER <br />METHOD QUAL DESCRIPTION <br />L96798 - WG330840 Aluminum (1312) <br />REPAD 15 06 05 01 <br />M6010B ICP <br />M6010B ICP <br />Inorganic Extended <br />Qualifier Report <br />ACZ Project ID: L96798 <br />RD For a solid matrix, the duplicate RPD (spike or matrix) <br />exceeded the control limit, which is attributable to the non - <br />homogeneity of the sample <br />ZG The ICP Serial Dilution was not used for data validation <br />because the sample concentration was less than 50 times <br />the MDL <br />WG330950 Antimony (1312) M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />Arsenic (1312) M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />M6020 ICP -MS ZB The ICP -MS Serial Dilution was not used for data validation <br />because the sample concentration was less than 100 times <br />the MDL <br />WG330840 Barium (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />M6010B ICP ZG The ICP Serial Dilution was not used for data validation <br />because the sample concentration was less than 50 times <br />the MDL <br />WG330950 Beryllium (1312) M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330840 Boron (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330950 Cadmium (1312) M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330840 Calcium (1312) M6010B ICP <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330950 Chromium (1312) M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330840 Cobalt (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG331050 Copper (1312) M6020 ICP -MS B5 Target analyte detected in prep / method blank at or above <br />the method reporting limit, but below trigger level or MCL <br />M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330840 Iron (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330950 Lead (1312) M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330840 Magnesium (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />Manganese (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />M6010B ICP ZG The ICP Serial Dilution was not used for data validation <br />because the sample concentration was less than 50 times <br />the MDL <br />WG330715 Mercury (1312) M7470A CVAA H3 Sample was received and analyzed past holding time <br />M7470A CVAA RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330840 Molybdenum (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />Page 25 of 39 <br />