My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-12-24_HYDROLOGY - P2011010
DRMS
>
Day Forward
>
Hydrology
>
Prospect
>
P2011010
>
2012-12-24_HYDROLOGY - P2011010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 11:35:00 AM
Creation date
1/3/2013 3:11:12 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
P2011010
IBM Index Class Name
HYDROLOGY
Doc Date
12/24/2012
Doc Name
WATER QUALITY 2012, 4TH QTR
From
RIO GRANDE SILVER
To
DRMS
Type & Sequence
MD2
Email Name
RCO
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334 -5493 <br />Rio Grande Silver, Inc. <br />ACZ ID WORKNUM PARAMETER <br />METHOD QUAL DESCRIPTION <br />L96798 - WG330840 Aluminum (1312) <br />REPAD 15 06 05 01 <br />M6010B ICP <br />M6010B ICP <br />Inorganic Extended <br />Qualifier Report <br />ACZ Project ID: L96798 <br />RD For a solid matrix, the duplicate RPD (spike or matrix) <br />exceeded the control limit, which is attributable to the non - <br />homogeneity of the sample <br />ZG The ICP Serial Dilution was not used for data validation <br />because the sample concentration was less than 50 times <br />the MDL <br />WG330950 Antimony (1312) M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />Arsenic (1312) M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />M6020 ICP -MS ZB The ICP -MS Serial Dilution was not used for data validation <br />because the sample concentration was less than 100 times <br />the MDL <br />WG330840 Barium (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />M6010B ICP ZG The ICP Serial Dilution was not used for data validation <br />because the sample concentration was less than 50 times <br />the MDL <br />WG330950 Beryllium (1312) M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330840 Boron (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330950 Cadmium (1312) M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330840 Calcium (1312) M6010B ICP <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330950 Chromium (1312) M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330840 Cobalt (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG331050 Copper (1312) M6020 ICP -MS B5 Target analyte detected in prep / method blank at or above <br />the method reporting limit, but below trigger level or MCL <br />M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330840 Iron (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330950 Lead (1312) M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330840 Magnesium (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />Manganese (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />M6010B ICP ZG The ICP Serial Dilution was not used for data validation <br />because the sample concentration was less than 50 times <br />the MDL <br />WG330715 Mercury (1312) M7470A CVAA H3 Sample was received and analyzed past holding time <br />M7470A CVAA RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG330840 Molybdenum (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />Page 25 of 39 <br />
The URL can be used to link to this page
Your browser does not support the video tag.