My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1997-07-21_GENERAL DOCUMENTS - M1977493
DRMS
>
Day Forward
>
General Documents
>
Minerals
>
M1977493
>
1997-07-21_GENERAL DOCUMENTS - M1977493
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2021 7:12:13 AM
Creation date
12/5/2012 9:17:42 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977493
IBM Index Class Name
GENERAL DOCUMENTS
Doc Date
7/21/1997
Doc Name
System Testing
From
Plexco
To
DMG
Permit Index Doc Type
General Correspondence
Media Type
D
Archive
No
Tags
DRMS Re-OCR
Description:
Signifies Re-OCR Process Performed
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
107/21/1997 08:45 3035724444 CROW COMPANY PAGE 03 <br /> Champ <br /> Plexco - W <br /> Test Pressure Table 1 Test Phase Make-up Amount <br /> Test pressure may be limited by valves,or other <br /> lower pressure rated components. Such c►altoot/t0o urft.ut Pi <br /> components may not withstand the required test N`siW(10.) 1 Test <br /> 2 Hour 3 Test <br /> pressure. They should be either removed,or Te:c 1'at 1'�s� <br /> Isolated from the lest section to avoid possible 3 0.10 0.15 0.1s <br /> damage,or failure of these devices. Isolated 4 0.13 0.25 0.40 <br /> equipment should be vented. 6 0.30 0.60 0.90 <br /> !' For pressure piping systems the maximum 8 0.50 1.0 1.5 <br /> allowable test pressure Is 1-1/2 times the 10 0.75 1.3 2A <br /> system design operating pressure at the lowest 12 1.1 2.3 3.4 <br /> point in the section under test,provided dw,. <br /> test pressure limiting components or devices 14 1.4 2.9 4.2 <br /> have been isolated,or removed ftow the test 16 1.7 3.3 5.0 <br /> Section. 1s 2.2 4.3 6.5 <br /> • If a lower pressure rated device or component 20 2.8 5-5 8.0 <br /> cannot be removed or isolated,then the test 22 3.5 7.o 10.5 <br /> pressure is limited to the pressure rating of 24 4.5 9.9 13.5 <br /> that device. 26 5.0 10.0 15.0 <br /> • For non-pressure,low pressure,or gravity 28 5.5 11.1 16.3 <br /> flow(intermittent pressure)systems.consult 30 6.3 12.7 19.2 <br /> Plexco/Spimlite Technical Personnel to <br /> determine maximum allowable test pressure. 32 7.0 1a.3 21.5 <br /> 34 9.0 16.2 243 <br /> 36 9.0 18.0 27.0 <br /> Test Duration <br /> For any test pressure fYvm 1 to 1-112 times the HYDROSTATIC TESTING <br /> system operating design pressure,the total test <br /> time including initial pressurization,initial <br /> expansion.and time at test pressure,must not General <br /> exceed eight(9)hours. If the test Is not <br /> completed due to leakage,equipment failure, PIPING SYSTEM PRESSURE TESTING <br /> etc.,depressurize the test section,then allow it USING HYDROSTATIC PROCEDURES IS <br /> to"relax"for at least eight(S)hours before RECOMMENDED. The preferred testing <br /> bringing the test section up to test pressure medium is clean water,but other liquids may be <br /> suitable. The test section should be completely <br /> filled with liquid. Take care to bleed off any <br /> trapped air. While the test section is filling, <br /> venting at high points may be necessary to purge <br /> air pockets. Venting may be provided by <br /> loosening flanges.or by using equipment vents. <br /> Redghten any loosened flanges before applying <br /> test pressure. <br />
The URL can be used to link to this page
Your browser does not support the video tag.