My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-09-06_REVISION - M2008070 (18)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M2008070
>
2012-09-06_REVISION - M2008070 (18)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 2:25:46 PM
Creation date
9/13/2012 12:30:40 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2008070
IBM Index Class Name
Revision
Doc Date
9/6/2012
Doc Name
AM-01 APPENDIX H: CONSTRUCTION QUALITY ASSURANCE CONTROL PLAN
From
WESTERN GRAVEL
To
DRMS
Type & Sequence
AM1
Email Name
THM
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Western Gravel E &P Waste Disposal Facility October 2011 <br />CQA/QCP Page 4 of 19 <br />Table 1- Moisture - Density Field Testing Methods <br />Parameter <br />Test Method <br />Moisture Content <br />ASTM D6938 <br />(Nuclear) <br />1 field compaction test <br />(ASTM D6938) per <br />1,000 cy <br />Soil Density <br />ASTM D6938 <br />(Nuclear) <br />Leak Detection Clays <br />Moisture Content <br />ASTM D2216 <br />(Oven Dried) <br />1 per Proctor or per <br />material type <br />Table 2 — Compaction/Moisture Specifications and Minimum Field Testing Frequencies <br />Fill Type <br />Compaction/Moisture Specification <br />Minimum Test Frequency <br />Embankment Backfill <br />Minimum 95% ASTM D698 @ -3 to +3% <br />of optimum moisture content <br />1 field compaction test <br />(ASTM D6938) per <br />1,000 cy <br />Standard Proctor <br />ASTM D698 <br />1 per 10000 cy or <br />per material type <br />Leak Detection Clays <br />Minimum 95% ASTM D698 @ -3 to +3% <br />of optimum moisture content <br />1 field compaction test <br />per 100 cy or 1 per day <br />Table 3 — Laboratory Testing Methods and Minimum Testing Frequencies <br />Material <br />Test <br />Test Method <br />Construction <br />Minimum Test <br />Frequency <br />PreConstruction <br />Minimum Test <br />Frequency <br />Embankment Backfill <br />(Structural Fill) <br />Standard Proctor <br />ASTM D698 <br />1 per 10000 cy or <br />per material type <br />1 per 2500 yd <br />Atterberg Limit <br />ASTM 4318 <br />1 per Proctor or per <br />material type <br />1 per 2500 yd <br />Grain Size Analysis <br />ASTM D422 <br />1 per Proctor or per <br />material type <br />1 per 2500 yd <br />One -point Proctor <br />ASTM D698 <br />1per 5000 cy placed <br />Leak Detection Clays <br />Atterberg Limit <br />ASTM 4318 <br />1 per day <br />1 per 2500 yd <br />Grain Size <br />ASTM 422 <br />1 per day <br />1 per 2500 yd <br />Hydraulic Conductivity <br />ASTM 5084 or Equivalent <br />If required <br />1 per 2500 yd <br />Leak Detection Sands <br />Atterberg Limit <br />ASTM 4318 <br />1 per day <br />1 per 2500 yd <br />Grain Size <br />ASTM 422 <br />1 per day <br />1 per 2500 yd <br />Hydraulic Conductivity <br />ASTM 434 or Equivalent <br />1 per cell <br />1 per 2500 yd <br />chate Collection Gravels <br />Grain Size <br />ASTM 422 <br />1 per day <br />1 per 2500 yd <br />Hydraulic Conductivity <br />ASTM 434 or Equivalent <br />1 per cell <br />1 per 2500 yd <br />NWCC INC. <br />
The URL can be used to link to this page
Your browser does not support the video tag.