2012-09-06_REVISION - M2008070 (18)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M2008070
>
2012-09-06_REVISION - M2008070 (18)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 2:25:46 PM
Creation date
9/13/2012 12:30:40 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2008070
IBM Index Class Name
Revision
Doc Date
9/6/2012
Doc Name
AM-01 APPENDIX H: CONSTRUCTION QUALITY ASSURANCE CONTROL PLAN
From
WESTERN GRAVEL
To
DRMS
Type & Sequence
AM1
Email Name
THM
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Western Gravel E &P Waste Disposal Facility October 2011 <br />CQA/QCP Page 3 of 19 <br />analyses. One hydraulic conductivity tests will be conducted on the gravels as they are placed. Table 3 <br />shows the required laboratory tests and testing frequencies for the gravels prior to and during <br />construction. Care shall be taken not to damage the liner materials and HDPE leachate collection pipe <br />during the placement of the gravels. The CQA Engineer shall observe the placement of the gravels. There <br />is no numerical compaction specification for the gravels being placed as part of the leachate collection <br />system; however, placement and light compaction shall be conducted to the satisfaction of the CQA <br />Engineer. <br />Protective Soil Cover /Operations Laver <br />The protective soil cover materials /operations layer to be placed under the leachate collection gravels, <br />over the one -sided geonet placed along the side slopes and over the geotextile fabric placed over the <br />leachate collection gravels shall be relatively permeable material consisting of sandy or gravelly soil. <br />There are no specific gradation specifications for these materials other than the maximum particle size <br />will be 2 inches for the operations layer and a maximum particle size of 3/8 inch for the protective soils <br />placed directly over the liner materials and under the leachate gravels. The CQA Engineer shall approve <br />the materials being used and observe the placement of these materials. There is no numerical compaction <br />specification for these materials; however, placement and light compaction shall be conducted to the <br />satisfaction of the CQA Engineer. <br />Anchor Trench Backfill <br />The soils used as anchor trench backfill shall consist of the on -site soils removed from the anchor trench <br />excavation. The anchor trench backfill materials will be placed in loose 12 to 18 inch maximum lifts and <br />wheel - rolled or compacted with a hand operated compactor to the satisfaction of the CQA Engineer. Care <br />shall be taken not to damage the liner materials during compacti on of the anchor trench backfill materials. <br />The CQQ Engineer shall observe the compaction operations as the anchor trenches are backfilled. There <br />are no prescribed quantitative tests for these backfill materials; however, at the discretion of the CQA <br />Engineer, laboratory and field compaction testing may be requested. <br />Riprap <br />Riprap used in the drainage channels shall consist of hard, dense, durable stone resistant to weathering. <br />The riprap shall have a specific gravity of at least 2.5. Material used fo r riprap must be approved by CQA <br />Engineer prior to placement. No specific testing of this material is required. However, the CQA <br />Engineer may require the contractor to furnish laboratory abrasion resistance testing if in the CQA <br />Engineer's opinion the stone is marginal or unacceptable. Nominal stone size and total thickness of riprap <br />shall be as shown on the Design and Construction Plans. Control of the gradation will be by visual <br />inspection performed by the CQA Engineer. A layer of Mirafi 160N or equivalent geotextile fabric shall <br />be placed over the finished subgrade surface prior to placement of the riprap. <br />NWCC INC. <br />