My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2011-08-22_HYDROLOGY - P2011009
DRMS
>
Day Forward
>
Hydrology
>
Prospect
>
P2011009
>
2011-08-22_HYDROLOGY - P2011009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 4:37:06 PM
Creation date
3/28/2012 2:33:32 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
P2011009
IBM Index Class Name
HYDROLOGY
Doc Date
8/22/2011
Doc Name
LOWER MTN TOP QUARTERLY WATER QUALITY REPORT
From
ST. SOPHIA HOLDING
To
DRMS
Email Name
RCO
SSS
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334 -5493 <br />St. Sophia Holding Ltd. <br />ACZ ID WORKNUM PARAMETER <br />METHOD <br />QUAL DESCRIPTION <br />L89127 -02 WG305358 Biochemical Oxygen Demand (5 day) SM521OB <br />REPAD.15.06.05.01 <br />Inorganic Extended <br />Qualifier Report <br />ACZ Project ID: L89127 <br />HF BOD analysis performed outside of 24 -hour hold time <br />stated in the method but within 48 -hour hold time stated in <br />40 CFR. <br />SM5210B K5 The dilution water D.O depletion was > 0.2 mg/L. <br />WG305522 Chemical Oxygen Demand M410.4 M1 Matrix spike recovery was high, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />M410.4 RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG306490 Chloride SM4500CI -E RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG305302 Chromium, Hexavalent SM3500Cr -D HE Analysis performed past holding time. Method holding time <br />is less than or equal to 7 days and sample was received <br />with less than half of the holding time remaining (refer to <br />item C5 of ACZ's Terms & Conditions). <br />SM3500Cr -D RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG305298 Coliforms, fecal SM9222D - Membrane Filter HE Analysis performed past holding time. Method holding time <br />is less than or equal to 7 days and sample was received <br />with less than half of the holding time remaining (refer to <br />item C5 of ACZ's Terms & Conditions). <br />WG305585 Cyanide, total M335.4 - Colorimetric w/ RA Relative Percent Difference (RPD) was not used for data <br />distillation validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG306057 Cyanide, WAD SM4500 -CN I- Colorimetric w/ RA Relative Percent Difference (RPD) was not used for data <br />distillation validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG306006 Fluoride SM4500F -C RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG305323 Nitrate /Nitrite as N, dissolved M353.2 - Automated Cadmium RA Relative Percent Difference (RPD) was not used for data <br />Reduction validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />Nitrite as N, dissolved M353.2 - Automated Cadmium RA Relative Percent Difference (RPD) was not used for data <br />Reduction validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG306474 Nitrogen, ammonia M350.1 - Automated Phenate RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG306526 Nitrogen, total Kjeldahl M351.2 - TKN by Block Digester M2 Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />M351 2 - TKN by Block Digester RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG305600 Phenol 420.4, Manual Distillation RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG306511 Phosphorus, total M365.1 - Auto Ascorbic Acid RA Relative Percent Difference (RPD) was not used for data <br />(digest) validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG305493 Residue, Non - Filterable (TSS) @105C SM2540D RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG305407 Sulfide as S 376 2 - Methylene Blue RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />Page 35 of 68 <br />
The URL can be used to link to this page
Your browser does not support the video tag.