Laserfiche WebLink
Product Used at <br />CC &V <br />Listed Chemical <br />RQ of listed <br />Chemical <br />(pounds) <br />Density of <br />product <br />(pounds /gallon) <br />Concentration <br />of Listed <br />Chemical ( %) <br />RQ of Product <br />(gallons) <br />1,000 (2) <br />Diesel or Gasoline <br />Diesel or Gasoline <br />Antifreeze <br />Ethylene Glycol <br />5,000 <br />8.34 <br />95.0% <br />631.07 <br />Sodium Hydroxide <br />Sodium Hydroxide <br />1,000 <br />12.71 <br />50.0% <br />157.36 <br />Hydrochloric Acid <br />Hydrochloric Acid <br />5,000 <br />9.83 <br />36.0% <br />1,412.91 <br />Antiscalant <br />Phosphoric Acid <br />100 <br />8.92 <br />10.0% <br />112.11 <br />Sodium Hypochlorite <br />Sodium Hypochlorite <br />100 <br />Calcium Hypochlorite <br />Calcium Hypochlorite <br />10 <br />Cyanide Solutions <br />Sodium Cyanide (3) <br />10 <br />8.34 <br />0.010% <br />11,990.41 <br />Cyanide Solutions <br />Sodium Cyanide (3) <br />10 <br />8.34 <br />0.015% <br />7,993.61 <br />Cyanide Solutions <br />Sodium Cyanide (3) <br />10 <br />8.34 <br />24.0% <br />5.00 <br />Cyanide Solutions <br />Sodium Cyanide (3) <br />10 <br />8.34 <br />25.0% <br />4.80 <br />Cyanide Solutions <br />Sodium Cyanide (3) <br />10 <br />8.34 <br />26.0% <br />4.61 <br />Cyanide Solutions <br />Sodium Cyanide (3) <br />10 <br />8.34 <br />27.0% <br />4.44 <br />Cyanide Solutions <br />Sodium Cyanide 13) <br />10 <br />8.34 <br />28.0% <br />4.28 <br />Cyanide Solutions <br />Sodium Cyanide (3) <br />10 <br />8.34 <br />29.0% <br />4.13 <br />This SRP is the guide for prevention and expedited control of "releases" of the above - listed <br />substances to ground or waters when such releases are the responsibility of CC &V This SRP is to <br />be used by CC &V Team Members to assist in responding to, containing, remediating and recording, <br />and reporting responses to releases. Names and telephone numbers of CC &V Team Members and <br />other persons to be notified are listed on the front cover and in the ERP under the CONTACTS tab. <br />Transporter contacts are listed in the ERP under the CONTACTS tab. The external reporting <br />contacts and agencies to whom certain releases are to be reported by representatives of the <br />Environmental Resources are also listed in the ERP under the CONTACTS tab. <br />1.1 External Reporting - Reportable Quantities <br />Releases that occur out of doors and outside an engineered containment area and which meet or <br />exceed the numeric thresholds known as Reportable Quantities ( "RQ ") as listed in Table 1, require <br />reporting to outside county, state and /or federal agencies. Spills or releases of these substances <br />should be immediately reported to the Environmental Resources Department and CC &V Team <br />supervisors. Use the Internal Spill Report form (Appendix A) provided in this SRP to document the <br />spill or release. Provide the Internal Spill Report to the Environmental Resources Department as <br />soon as possible within the same shift of the occurrence so that external reporting can be <br />accomplished within the required 24 hours. <br />Table 1 Reportable Quantities if Released to Land (')- Bulk Chemicals <br />(1) Discharge of oil in such quantities that result in exceedance of applicable receiving water quality standards or cause a film or <br />sheen upon the surface of the receiving water must be reported to the National Response Center. <br />(2) Into or upon the navigable waters of the U. S. or shorelines in a single event <br />(3) The Cyanide Containment Policy is included as Appendix D of this Plan. Use the graphs in Appendix E to calculate the <br />amount of cyanide released from known quantities and concentrations. <br />2 CC &V does not normally respond to releases that may occur as a result of a contractor or other activity conducted on <br />CC &V property under a lease or contractual arrangement. Rather, any contractor or other authorized activity should include <br />clear and enforceable requirements for that other entity to have an acceptable SPCC Plan and to have control and response <br />procedures in place. <br />Spill Response Plan <br />EMS: AGANAICCV <br />G: \EMS\Plans\Emergency Response Plans\SRP Plan \SRP Plan.doc <br />Printed Copies are Uncontrolled <br />August 17, 2010 <br />Doc. # E -006 <br />Revision 05 <br />2 <br />