Laserfiche WebLink
Test and ASTM <br />Designation <br />Subgrade <br />(cy) <br />Structural <br />Fill <br />(cy) <br />Select <br />Structural <br />Fill <br />(cy) <br />Underdrain <br />FM <br />(cy) <br />Compaction <br />(ASTM D698) <br />50,000 <br />50,000 <br />50,000 <br />-- <br />Particle Size <br />(ASTM C117, C136, DI 140) <br />50,000 <br />50,000 <br />50,000 <br />5,000 <br />Atterberg Limit <br />(ASTM D4318) <br />-- <br />50,000 <br />-- <br />5,000 <br />Moisture Content <br />(ASTM D2216) <br />2,000 <br />2,000 <br />2,000 <br />5,000 <br />Nuclear Density <br />ASTM D2922 <br />2,000 <br />2,000 <br />2,000 <br />-- <br />TABLE 1 <br />SOIL CONSTRUCTION TESTING FREQUENCY' <br />VOLUME PER TEST <br />Section 01400.1 Page 9 of 10 January 14, 2011 <br />Earthworks CQA Plan Revision 0 <br />1. Tests shall be performed at the specified frequency or one per material type, whichever is greater. <br />2. Use the USCS for description and identification (ASTM D2488). <br />3. In -place moisture content. <br />amec( <br />S \Protects \1125G Squaw Gulch Valley Leach Facililty Designll - Tech Specs \01400 1 r0 doc <br />