Laserfiche WebLink
Test and <br />ASTM <br />Designation <br />Low Volume Solution Collection Fill, Bedding Fill, <br />Leak Detection Fill, <br />and Pipe Bedding Fill <br />(cy) <br />Soil <br />Liner <br />Fill <br />(cy) <br />Drain <br />Cover <br />Fill <br />(cy) <br />Compaction <br />(ASTM D698) <br />-- <br />4,000 <br />-- <br />Particle Size2 <br />(ASTM C117, C136, <br />D1140) <br />10,000 <br />4,000 <br />20,000 <br />Atterberg Limit <br />(ASTM D4318) <br />10,000 <br />4,000 <br />20,000 <br />Moisture Content <br />(ASTM D2216) <br />10,000 <br />500 <br />20,000 <br />Permeability <br />(ASTM D5084/2434) <br />-- <br />4,000 <br />-- <br />Nuclear Density <br />-- <br />500 <br />-- <br />TABLE 2 <br />SOIL CONSTRUCTION TESTING FREQUENCY <br />VOLUME PER TEST' <br />1. Tests shall be performed at the specified frequency or one per material type, whichever is greater. <br />2. Use the USCS for description and identification (ASTM D2488). <br />3. In -place Moisture Content. <br />4. Permeability testing will be performed during the processing of the Soil Liner Fill material, certifying the <br />processed stockpile. <br />* ** END OF SECTION * ** <br />Section 01400.1 Page 10 of 10 January 14, 2011 <br />Earthworks CQA Plan Revision 0 <br />S \Protects \1125G Squaw Gulch Valley Leach Facililty Design\I - Tech Specs \01400 1 r0 doc <br />ame0 <br />