D. SHALLOW INJECTION WELL OPERATION AND MAINTENANCE <br />1. Injection Locations. Injection location shall be limited to the injection well shown <br />in Figure 1 of Appendix A of this permit. <br />2. Injection Fluid Limitation. The permittee shall not inject any hazardous <br />substances, as defined by 40 CFR, Part 261, at any time during the operation of the injection <br />well; and further, no substances other than the groundwater pumped from the A2 Sandstone of <br />the Upper Fox Hills Formation shall be injected, unless allowed by permit modification. <br />3. Injection Fluid Analysis. Before the aquifer-pump test begins, samples of A2 <br />sandstone groundwater shall be collected from the injection well. Before injection begins, <br />composite samples of the groundwater pumped from the A2 Sandstone of the Upper Fox Hills <br />Formation shall be collected from the storage tanks. These samples shall be analyzed for Total <br />Coliforms using an EPA approved method, Total Metals as shown in Table 1, Volatile Organic <br />Compounds using EPA Method 524.2, Semi-volatile Organic Compounds using EPA Method <br />525.2, and Total Petroleum Hydrocarbons using EPA Method 1664. Alternative analytical <br />methods may be used with approval by EPA before sample analyses are performed. <br />Table 1: Permit Limits and Approved Analytical Methods for Total Metals <br />Parameter Name Permit/LL)mit Standard Type* Analytical Methods <br />!Arsenic 10 MCL I200.7, 200.8, 2009 <br /> <br />;Barium - <br />i 2,000 -r---------____ <br />IMCL ?? <br />;200.7, 200.8 <br />'Cadmium 5 !MCL ;200.7, 200.8, 200.9 <br />Chromium(total <br />;Lead i 100 <br />15 IMCL <br />IMCL-TT 200.7, 200.8, 200.9 <br />1200.8, 200.9 _ - <br />_ <br />;Mercury (inorganic) 2 _ <br />T EMCL I245.1, 245.2, 200.8 <br />Selenium 50 IMCL 0 200.9 _ <br />:Silver ??- 100 HA-Lifetime 1200.7, 200.8, 200.9 <br />4. Best Management Practices. The permittee shall operate the injection system in <br />such a way that best environmental management practices are followed. Best Management <br />Practices in the case of this permit shall consist of preventing the contamination of groundwater <br />extracted from the A2 sandstone of the Upper Fox Hill Formation before it is reinjected. To <br />verify the storage tanks will not contaminate the A2 sandstone groundwater during storage, the <br />permittee shall verify that requirements of the Division of Reclamation, Mining, and Safety <br />(DRMS) have been met by submitting the following information to the Director: <br />i. Written documentation that the requirement for cleaning of the storage tanks has <br />been fulfilled. <br />ii. Written documentation that the requirement for providing the history of tank <br />contents, including at least the most recent previous tank use event, has been <br />fulfilled. <br />Powertech (USA), Incorporated <br />Final UIC Class V Permit No. C051237-08412 <br />Page 3 of 14