• <br />0 <br />• <br />ameO <br />During placement of fill materials, when the ambient air temperature was less than 32°F for <br />longer than 1 hour in the previous 24 hours, AMEC was required to monitor the fill <br />temperatures at depths of 3 inches and 6 inches, at a frequency of 6 tests per acre, and <br />calculate the average fill temperature from the lower temperature of the 3-inch and 6-inch <br />tests. No frozen materials were placed during the construction of the 2010 Phase 5 VLF. Fill <br />temperature monitoring in summarized in Table 3. <br />AMEC Earth & Environmental, Inc. <br />2000 S. Colorado Blvd 2-1000 <br />Denver, CO 80222 <br />Tel 303-935-6505 <br />Fax 303-935-6575 vA".amec.com <br />37