Laserfiche WebLink
amec(v <br />• <br />4.1.3 Atterberg Limits <br />AMEC performed Atterberg limit testing of all fill materials. All fill materials, with the <br />exception of SF, SLF, SSF, and CSB were non-plastic. The SLF, SF, SSF, UF, LVSCF, <br />DCF, and CSB samples tested met project specifications for Atterberg Limits. <br />AMEC performed three CQA Atterberg limit of UF. The testing frequency (approximately <br />one test per 59 cubic yards) exceeded the minimum specified testing frequency of one test <br />per 5,000 cubic yards. The CQA Atterberg limit of OF met project specifications. The OF <br />CQA Atterberg limit results are presented in Appendix H-1 and summarized in Table 6. <br />AMEC performed four CQA Atterberg limit of the SSF. The testing frequency (approximately <br />one test per 221 cubic yards) exceeded the minimum specified testing frequency of one test <br />per 50,000 cubic yards. The CQA Atterberg limit of SSF met project specifications. The <br />SSF CQA Atterberg limit results are presented in Appendix H-1 and summarized in Table 7. <br />AMEC performed fifty-three CQA Atterberg limit of SF. The testing frequency <br />(approximately one test per 47,415 cubic yards) exceeded the minimum specified testing <br />frequency of one test per 50,000 cubic yards. The CQA Atterberg limit performed on SF met <br />project specifications. The SF CQA Atterberg limit results are presented in Appendix H-1 <br />and summarized in Table 8. <br />AMEC performed 17 CQA Atterberg limit of SLF. The testing frequency (approximately one <br />test per 3,138 cubic yards) exceeded the minimum specified testing frequency of one test <br />per 5,000 cubic yards. The CQA Atterberg limit performed of SLF met project specifications. <br />The SLF CQA Atterberg limit results are presented in Appendix H-1 and summarized in <br />Table 9. <br />AMEC performed twenty-one CQA Atterberg limit of LVSCF. The testing frequency <br />(approximately one test per 8,191 cubic yards) exceeded the minimum specified testing <br />frequency of one test per 10,000 cubic yards. The LVSCF CQA Atterberg limit met project <br />specifications, and the results are presented in Appendix H-1 and summarized in Table 10. <br />AMEC Earth & Environmental, Inc. <br />2000 S. Colorado Blvd 2-1000 <br />Denver, CO 80222 <br />Tel 303-935-6505 <br />Fax 303-935-6575 www.amec.com <br />28