My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1997-04-24_REVISION - M1977493 (17)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1977493
>
1997-04-24_REVISION - M1977493 (17)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/16/2021 5:41:06 PM
Creation date
8/31/2010 11:01:27 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977493
IBM Index Class Name
REVISION
Doc Date
4/24/1997
Doc Name
EPAS- Appendix F- Field Collection Parameters
From
Climax Molybdenum
To
DMG
Type & Sequence
SR2
Email Name
ACS
Media Type
D
Archive
No
Tags
DRMS Re-OCR
Description:
Signifies Re-OCR Process Performed
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_ _ _ —=Environmenta <br /> 4. Record temperature value for the sample from the bottom scale of the meter display <br /> in degrees Celsius. Allow time for the probe temperature to equilibrate with that of <br /> the sample solution before reading. Record the temperature value on the field data <br /> sheet and/or in the bound field logbook, as applicable. <br /> The YSI Model 33 meter has been factory-calibrated for temperature. The probe contains a <br /> precision thermistor temperature sensor of +0.1 degrees Celsius and +0.3 degrees Celsius at 40 <br /> degrees Celsius. Quarterly, check the meter against a National Institute of Standards and <br /> Technology-certified field laboratory thermometer. Agreement should by within 0.5 degrees <br /> Celsius. <br /> CONDUCTIVITY MEASUREMENT <br /> Probe Calibration Procedure <br /> At the beginning of each day, calibrate the conductivity cell (probe) and the meter together as a <br /> system to achieve maximum measurement accuracy in the field. The following method applies <br /> to the YSI Model 33 meter. If another meter is used, refer to manufacturer's directions. <br /> Calibration of the probe and meter shall be accomplished using certified YSI Conductivity <br /> Calibrator Solution #3161, #3163, or equivalent certified calibrator solution. The YSI Model 33 <br /> meter shall be calibrated as follows: <br /> 1. Select a glass or plastic container several inches taller than the probe and at least 2- <br /> inches greater in diameter. Clean this container with DS/DI water and dry with a <br /> clean cloth or paper towel. <br /> • <br /> CO2127 <br />