My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-12-21_REVISION - M1980244 (43)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1980244
>
2009-12-21_REVISION - M1980244 (43)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 5:52:24 PM
Creation date
12/30/2009 8:52:46 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
REVISION
Doc Date
12/21/2009
Doc Name
QA Liner Recert- App. A, Phase IVa and IVc Certification Documentation
From
CC&V
To
DRMS
Type & Sequence
AM9
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
August 2002 -22- 003 -2203 <br />50,000 cubic yards. The CQA gradations of SSF met project specifications. The SSF CQA <br />gradation results are presented in Appendix 1 -1 and summarized in Table 6. <br />Golder performed 1 CQA gradation of LDF. The testing frequency (approximately one test per <br />84 cubic yards) exceeded the minimum specified testing frequency of one test per 10,000 cubic <br />yards. The CQA gradation of LDF met project specifications. The LDF CQA gradation results <br />are presented in Appendix I -1 and summarized in Table 7. One LDF test failed to meet <br />specifications. The LDF was removed and replaced with LDF meeting the project <br />specifications. <br />Golder performed I I CQA gradations of SF. The testing frequency (approximately one test per <br />40,090 cubic yards) exceeded the minimum specified testing frequency of one test per <br />50,000 cubic yards. The CQA gradations performed on SF met project specifications. The SF <br />CQA gradation results are presented in Appendix I -1 and summarized in Table 8. <br />i Golder performed 12 CQA gradations of SIX. The testing frequency (approximately one test <br />per 4,413 cubic yards) exceeded the minimum specified testing frequency of one test per <br />5,000 cubic yards. The CQA gradations performed of SLF met project specifications. The SLF <br />CQA gradation results are presented in Appendix I -1 and summarized in Table 9. <br />Golder performed 6 CQA gradations of DCF. The testing frequency (approximately one test <br />per 17,653 cubic yards) exceeded the minimum specified testing frequency of one test per <br />20,000 cubic yards. The DCF CQA gradations met project specifications, and the results are <br />presented in Appendix I -1 and summarized in Table 10. <br />Golder performed 1 CQA gradation of FSB. No testing frequency was identified in the CQA <br />Plan for this material. The CQA gradation performed on FSB met project specifications. The <br />FSB gradation results are presented in Appendix I -I and summarized in Table 11. <br />is <br />rWM2031040wceftnepOSOMD322030400.04740w.dw Golder Associates <br />