My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-12-21_REVISION - M1980244 (43)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1980244
>
2009-12-21_REVISION - M1980244 (43)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 5:52:24 PM
Creation date
12/30/2009 8:52:46 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
REVISION
Doc Date
12/21/2009
Doc Name
QA Liner Recert- App. A, Phase IVa and IVc Certification Documentation
From
CC&V
To
DRMS
Type & Sequence
AM9
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
August 2002 -21- <br />► Moisture content (ASTM D2216); <br />► Atterberg limits (ASTM D4318); <br />► Standard Proctor compaction (ASTM D698); <br />► Point load (ASTM D5731); <br />► Permeability (ASTM D5084, Method D); <br />► In -place density testing (ASTM D2922); <br />► Soil description (ASTM D2488); and <br />► Bulk specific gravity (ASTM C 127). <br />003 -2203 <br />Golder conducted appropriate tests as required by the specifications for UF, SSF, FSB, PBF, <br />LDF, Subgrade Structural Fill, SF, SLF, and DCF. <br />The laboratory test results are summarized in Tables 5 through 12 and presented in Appendix 1. <br />4. 1.1 Grain Size Distribution <br />Golder analyzed the grain size distribution (gradation) of samples of UF, SSF, FSB, PBM, <br />LDF, SF, SLF, and DCF. The results of gradation analyses are presented in Appendix I -1 and <br />summarized in Tables 5 through 12 and Table 18. <br />Golder performed 1 CQA gradation of UF. The testing frequency (approximately one test per <br />406 cubic yards) exceeded the minimum specified testing frequency of one test per 5,000 cubic <br />yards. The CQA gradation of OF met project specifications. The OF CQA gradation results are <br />presented in Appendix I -1 and summarized in Table 5. <br />Golder performed 2 CQA gradations of the SSF. The testing frequency (approximately one test <br />per 270 cubic yards) exceeded the minimum specified testing frequency of one test per <br />OP <br />1. WO= 3W4W% CenRepO8021003=3:Oao.0g741w.0oc Golder Associates <br />
The URL can be used to link to this page
Your browser does not support the video tag.