My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-12-21_REVISION - M1980244 (43)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1980244
>
2009-12-21_REVISION - M1980244 (43)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 5:52:24 PM
Creation date
12/30/2009 8:52:46 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
REVISION
Doc Date
12/21/2009
Doc Name
QA Liner Recert- App. A, Phase IVa and IVc Certification Documentation
From
CC&V
To
DRMS
Type & Sequence
AM9
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
August 2002 -23- 003 -2203 <br />Golder performed 2 CQA gradation of Pipe Bedding Material (PBM). No testing frequency <br />• was identified in the CQA Plan for this material. The CQA gradation performed on PBM. met <br />project specifications. The PBM gradation results are presented in Appendix I -1 and <br />summarized in Table 12. <br />Golder performed 1 CQA gradation of Granular Filter Material. (GFM). No testing frequency is <br />identified in the CQA plan for this material. The CQA gradations performed of GFM met <br />project specifications. The GFM CQA gradation results are presented in Appendix I -1 and <br />summarized in Table 18. <br />4.1.2 Moisture Content <br />Golder measured oven moisture contents of UF, SSF, FSB, PBM, LDF, SF, SSF, SLF and <br />DCF as part of the CQA program. Moisture content data were presented in Appendix I -1. <br />4.1.3 Atterber Limits <br />Golder performed Atterberg limit testing of all fill materials. All fill materials, with the <br />exception of SF and SLF were non - plastic. The SLF, SF, UF, LDF, DCF, FSB, and PBM <br />samples tested met project specifications for Atterberg Limits. <br />The testing frequency (approximately one test per 4,413 cubic yards for SLF) exceeded the <br />minimum specified testing frequency. The plasticity index of the CQA SLF samples ranged <br />from 22 to 29, meeting the project specification of plasticity index greater than or equal to 10. <br />Atterberg limit test results for SLF are presented in Appendix I -1 and summarized in Table 9. <br />I:1 O=03404001CUIRWMZ 03=03.040004740 tdoe Golder Associates <br />