Laserfiche WebLink
Portal Shed/Compressor Shed Combination <br />The remains of this structure are shown on drawing sheets 1 and 5 <br />of 9. All above grade portions of these structures (all roofing <br />and siding, all framing, all remaining inside contents) shall be <br />demolished or otherwise dismantled and removed down to the existing <br />grade or foundation elevation. All portions of the structure which <br />are not salvaged by the CONTRACTOR shall be disposed of by <br />back stowing materials within the inclined mine entry beginning at a <br />minimum distance of 50 ft. from the surface. Demolished materials <br />may also be removed from the site by hauling to an approved <br />landfill operation. <br />Electrical Service Distribution Station <br />The remains of this facility are shown on drawing sheets 1 and 5 of <br />9. ALL above grade portions of this structure including support <br />poles, sheet metal awning and frame, wood panels, electrical switch <br />boxes, equipment and wiring, shall be demolished or otherwise <br />dismantled, removed and/or disposed of to the same extent and using <br />the same performance standards specified in Section III.4.2.B.1 of <br />the Special Conditions. <br />3. Loadout/Tip le Building <br />This structure is shown on drawing sheets 1 and 4 of 9. ALL above <br />grade portions of this structure (all roofing and siding, all <br />framing, and all inside contents) shall be demolished or otherwise <br />dismantled and removed down to the existing grade or foundation <br />elevation. Non-salvaged portions of the structure shall be <br />disposed of either by backstowing within the inclined mine entry at <br />a minimum distance of 50 ft. from the surface, or by hauling to an <br />approved landfill operation. <br />4. Conveyor System <br />This structure is shown on drawing sheets 1 and 4 of 9. The above <br />grade portions of this structure extending from the loading <br />platform to the loadout/tipple building shall be demolished or <br />otherwise dismantled and removed down to the existing grade or <br />foundation elevation. Non-salvaged portions of the conveyor system <br />shall be disposed of either by back stowing within the inclined mine <br />entry at a minimum distance of 50 ft. from the surface, or by <br />hauling to an approved landfill operation. <br />5. Truck Scale Housing/Shed <br />This structure is shown on drawing sheet 3 of 9. The above grade <br />portions of this structure shall be demolished or otherwise <br />dismantled and removed down to the existing grade or foundation <br />elevation. Non-salvaged portions of the housing or shed shall be <br />disposed of either by back stowing within the inclined mine entry at <br />a minimum distance of 50 ft. from the surface, or by hauling to an <br />approved landfill operation. <br />-10- <br />