My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2004-10-18_REVISION - M1980244 (25)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1980244
>
2004-10-18_REVISION - M1980244 (25)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 5:49:54 PM
Creation date
11/22/2007 12:19:59 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
Revision
Doc Date
10/18/2004
Doc Name
Phase IVc Ore Storage Area Liner Certification Report
From
Anglo Gold
To
DMG
Type & Sequence
AM8
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
October 2004 -19- 043-2170 <br />r1 <br />U <br />r ~ <br />L J <br />i• <br />Golder performed six CQA gradations of SF. The testing frequency (approximately one test per <br />20,842 cubic yards) exceeded the minimum specified testing frequency of one test per 50,000 cubic <br />yards. The CQA gradations performed on SF met project specifications. The SF CQA gradation <br />results aze presented in Appendix I-1 and summarized in Table 9. <br />Golder performed 21 CQA gradations of SLF. The testing frequency (approximately one test per <br />4,592 cubic yards) exceeded the minimum specified testing frequency of one test per 5,000 cubic <br />yards. The CQA gradations performed on SLF met project specifications. The SLF CQA gradation <br />results aze presented in Appendix I-1 and summarized in Table 10. <br />Golder performed ten CQA gradations of DCF. The testing frequency (approximately one test per <br />19,290 cubic yards) exceeded the minimum specified testing frequency of one test per 20,000 cubic <br />yards. The DCF CQA gradations met project specifications, and the results are presented in <br />Appendix I-1 and summarized in Table 11. <br />Golder performed two CQA gradations of FSB. No testing frequency was identified in the CQA Plan <br />for this material. The CQA gradation performed on FSB met project specifications. The FSB <br />gradation results are presented in Appendix I-1 and summarized in Table 12. <br />4.1.2 Moisture Content <br />Golder measured oven moisture contents of iJF, SSF, FSB, LDF, PBM, SF, SLF, and DCF as par[ of <br />the CQA program. Moisture content data is presented in Appendix I-1. <br />4.13 Atterbere Limits <br />Golder performed Atterberg limit testing of all fill materials. All fill materials, with the exception of <br />SF and SLF were non-plastic. The SLF, SF, LTF, LDF, PBM, SSF, DCF, and FSB samples tested met <br />project specifications for Atterberg Limits. <br />The SLF testing frequency (approximately one test per 4,592 cubic yards for SLF) exceeded the <br />minimum specified testing frequency. The plasticity index of the CQA SLF samples ranged from 21 <br />to 32, meeting the project specification of plasticity index greater than or equal to 10. •Atterberg limit <br />test results for SLF aze presented in Appendix I-1 and summarized in Table 10. <br />ew+~snaaaman~nwrveaaonauma.aaoes~a~.cvaenrvca« Golder Associates <br />
The URL can be used to link to this page
Your browser does not support the video tag.