Laserfiche WebLink
October 2004 -19- 043-2170 <br />r1 <br />U <br />r ~ <br />L J <br />i• <br />Golder performed six CQA gradations of SF. The testing frequency (approximately one test per <br />20,842 cubic yards) exceeded the minimum specified testing frequency of one test per 50,000 cubic <br />yards. The CQA gradations performed on SF met project specifications. The SF CQA gradation <br />results aze presented in Appendix I-1 and summarized in Table 9. <br />Golder performed 21 CQA gradations of SLF. The testing frequency (approximately one test per <br />4,592 cubic yards) exceeded the minimum specified testing frequency of one test per 5,000 cubic <br />yards. The CQA gradations performed on SLF met project specifications. The SLF CQA gradation <br />results aze presented in Appendix I-1 and summarized in Table 10. <br />Golder performed ten CQA gradations of DCF. The testing frequency (approximately one test per <br />19,290 cubic yards) exceeded the minimum specified testing frequency of one test per 20,000 cubic <br />yards. The DCF CQA gradations met project specifications, and the results are presented in <br />Appendix I-1 and summarized in Table 11. <br />Golder performed two CQA gradations of FSB. No testing frequency was identified in the CQA Plan <br />for this material. The CQA gradation performed on FSB met project specifications. The FSB <br />gradation results are presented in Appendix I-1 and summarized in Table 12. <br />4.1.2 Moisture Content <br />Golder measured oven moisture contents of iJF, SSF, FSB, LDF, PBM, SF, SLF, and DCF as par[ of <br />the CQA program. Moisture content data is presented in Appendix I-1. <br />4.13 Atterbere Limits <br />Golder performed Atterberg limit testing of all fill materials. All fill materials, with the exception of <br />SF and SLF were non-plastic. The SLF, SF, LTF, LDF, PBM, SSF, DCF, and FSB samples tested met <br />project specifications for Atterberg Limits. <br />The SLF testing frequency (approximately one test per 4,592 cubic yards for SLF) exceeded the <br />minimum specified testing frequency. The plasticity index of the CQA SLF samples ranged from 21 <br />to 32, meeting the project specification of plasticity index greater than or equal to 10. •Atterberg limit <br />test results for SLF aze presented in Appendix I-1 and summarized in Table 10. <br />ew+~snaaaman~nwrveaaonauma.aaoes~a~.cvaenrvca« Golder Associates <br />