My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2004-10-18_REVISION - M1980244 (25)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1980244
>
2004-10-18_REVISION - M1980244 (25)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 5:49:54 PM
Creation date
11/22/2007 12:19:59 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
Revision
Doc Date
10/18/2004
Doc Name
Phase IVc Ore Storage Area Liner Certification Report
From
Anglo Gold
To
DMG
Type & Sequence
AM8
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
October 2004 -18- 043-2170 <br />• • Soil description (ASTM D2488); and <br />• Bulk specific gravity (ASTM C 127). <br />Golder conducted appropriate tests as required by the specifications for UF, SSF, FSB, LDF, PBM, <br />SF, SLF, and DCF. <br />The laboratory test results are summarized in Tables 5 through 12 and presented in Appendix I. <br />4.1.1 Grain Size Distribution <br />Golder analyzed the grain size distribution (gradation) of samples of UF, SSF, FSB, LDF, PBM, SF, <br />SLF, and DCF. The results of gradation analyses are presented in Appendix I-1 and summarized in <br />Tables 5 through 12. <br />Golder performed one CQA gradation of UF. The testing frequency (approximately one test per <br />400 cubic yards) exceeded the minimum specified testing frequency of one test per 5,000 cubic yards. <br />The CQA gradation of iIF met project specifications. The iJF CQA gradation results are presented in <br />• Appendix I-1 and summarized in Table 5. <br />Golder performed one CQA gradation of the SSF. The testing frequency (approximately one test per <br />2,030 cubic yards) exceeded the minimum specified testing frequency of one test per 50,000 cubic <br />yards. The CQA gradation of SSF met project specifications. The SSF CQA gradation results are <br />presented in Appendix I-1 and summazized in Table 6. <br />Golder performed one CQA gradation of LDF. The testing frequency (approximately one test per <br />250 cubic yards) exceeded the minimum specified testing frequency of one test per 10,000 cubic <br />yards. The CQA gradation of LDF met project specifications. The LDF CQA gradation results are <br />presented in Appendix I-1 and summarized in Table 7. <br />Golder performed one CQA gradation of PBM. No testing frequency was identified in the CQA Plan <br />for this material. The CQA gradations of PBM met project specifications. The PBM CQA gradation <br />results are presented in Appendix I-1 and summazized in Table 8. <br />• <br />~:wiawmo+ao¢enQnenrv<-iaawuximwau~xuxaneerv~a~ Golder Associates <br />
The URL can be used to link to this page