Laserfiche WebLink
<br />SECTION 3: PROTOCOL FOR SURFACE WATER SAMPLE COLLECTION AND <br />' HANDLING <br />3.1 Water Sample Handling and Management <br />Surface sample handling and management will be conducted in <br />' accordance with the procedures outlined in Section 2.1. <br />3.2 Surface Water Sample Collection <br />' This protocol outlines procedures and equipment for the collection <br />of representative surface water samples from the stream monitoring <br />stations. <br /> 3.2.1 Cleaning of SamolinP Ec~ui~ment: All equipment used for sample <br /> collection will be cleaned before sampling, and between samples. <br />' <br /> sampling buckets will be cleaned prior to initi al use, and after <br />' each subsequent use, in the following manner: <br /> (1) tap water rinse; <br /> (2) de-ionized water wash; <br /> <br /> (3) total air dry; and <br /> <br /> (4) wrapped in aluminum foil or plastic immediately after <br />' cleaning. <br />' 3.2.2 Sample Containers: Containers used in the collection of samples <br />will be supplied by the laboratory performing the analysis. The <br />' type of container used for sample collection will be dictated by <br />the parameter(s) for which the sample is to be analyzed. A listing <br /> <br />-21- <br /> <br />