Laserfiche WebLink
June 24,2003 -38- 003-2203.7 <br />• Prior to the deployment of geomembrane, Golder and Poly-Flex verified that the subgrade was free of <br />soft spots, protrusions, angular particles, abrupt grade changes, and loose soil. Golder and Poly-Flex <br />verified that the SLF, LVSCF, and BF surfaces had been proof-rolled, and that the SLF surface was <br />free of desiccation cracks. Where the surface of the SLF, LVSCF, or BF did not meet specifications, <br />Ames repaired the area and re-compacted the surface. Poly-Flex provided written certification of <br />geomembrane subgrade acceptance. The subgrade acceptance certificates are presented in <br />Appendix G. <br />Golder assigned each geomembrane panel a number, as follows: <br />• Single-sided textured 100-mil geomembrane panels deployed in the PSSA were <br />designated by L-79 through L-128, L-135 through L-269, L-312 through L-385, <br />L-396 through L-437, U-361, U-363, U-368 through U-380, and U-398 through <br />U-400; <br />• Smooth 100-mil geomembrane panels deployed in the PSSA were designated by <br />M-270 through M-311, M-438 through M-512, M-616 through M-654, U-01 <br />through U-360, U-364 through U-367, U-381 through U-397, and U-401 through <br />U-456; and <br />• • Double-sided textured 100-mil geomembrane panels deployed in the PSSA were <br />designated by L-426 through L-435, L-513 through L-516, L-519 through L-521, <br />L-527 through L-530, L-545 through L-551, and U-334 through U-362 (not <br />including U-361). <br />Golder marked the panel designation and roll number directly on each panel afrer it was deployed. <br />The geomembrane record drawings, showing the lower geomembrane panel layout and destructive <br />testing and the upper geomembrane panel layout and destructive testing, are presented in Record <br />Drawings No. 6 and No. 7 in Appendix A. <br />During geomembrane deployment, Golder measured sheet thickness with a micrometer. Golder <br />measured sheet thickness at five random locations along one edge of each geomembrane panel. The <br />average thickness specified for the 100-mil geomembrane was 100 mils. Project specifications for <br />100-mil geomembrane required that the average of the five thickness measurements be no less than <br />the 100 mils, and that no individual measurement be less than nominal thickness minus 10 mils <br />(i.e., 90-mil). The thickness monitoring provided by Golder indicated that all of the panels met or <br />exceeded project requirements. <br />• <br />1:100\1361\OJ00\inlCenPSSA0bWl0pJ220.1.0000.0]N31tep.e« Golder Associates <br />