My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2003-07-11_REVISION - M1980244
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1980244
>
2003-07-11_REVISION - M1980244
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 5:49:50 PM
Creation date
11/21/2007 1:19:51 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
Revision
Doc Date
7/11/2003
Doc Name
Phase IV PSSA Area Cert Report
From
DMG
To
Cripple Creek & Victor Gold
Type & Sequence
AM8
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
June 24.2003 -24- 003-2203.7 <br />• Golder performed eight CQA gradations of SLF. The testing frequency (approximately one test per <br />3,827 cubic yards) exceeded the minimum specified testing frequency of one test per 5,000 cubic <br />yards. The CQA gadations performed of SLF met project specifications. The SLF CQA gradation <br />results aze presented in Appendix I-1 and summazized in Table 9. <br />Golder performed three CQA gradations of BF. The testing frequency (approximately one test per <br />4,052 cubic yards) exceeded the minimum specified testing frequency of one test per 10,000 cubic <br />yards. The CQA gradations performed of BF met project specifications. The BF CQA gradation <br />results aze presented in Appendix I-1 and summarized in Table 10. <br />Golder performed 13 CQA gradations of LVSCF. The testing frequency (approximately one test per <br />9,87] cubic yards) exceeded the minimum specified testing frequency of one test per 10,000 cubic <br />yards. The LVSCF CQA gradations met project specifications, and the results are presented in <br />Appendix I-1 and summarized in Table 11. <br />Golder performed five CQA gradations of DCF. The testing frequency (approximately one test per <br />. 17,110 cubic yards) exceeded the minimum specified testing frequency of one test per 20,000 cubic <br />yards. The DCF CQA gradations met project specifications, and the results are presented in <br />Appendix I-1 and summarized in Table 12. <br />Golder performed one CQA gradations of SDCF. The testing frequency (approximately one test per <br />3,500 cubic yards) exceeded the minimum specified testing Frequency of one test per 20,000 cubic <br />yards. The SDCF gradations met project specifications, and the results are presented in Appendix I-I <br />and summarized in Table 13. <br />Golder performed one CQA gradation of FSB. There is no testing frequency for FSB. The CQA <br />gradation performed on FSB did not meet project specifications. However, this material was <br />approved by Golder as discussed in Section 1.4. The FSB gadation results are presented in <br />Appendix I-1 and summarized in Table 14. <br />4.1.2 Moisture Content <br />• Golder measured oven moisture contents of LTF, SSF, FSB, LDF, SF, SSF, SLF, BF, LVSCF, DCF, <br />and SDCF as part ofthe CQA program. Moisture content data are presented in Appendix I-1. <br />z:~oo~zanaeaou=~icenesseoeamoozzzoa.aaa.mwzz~p.a« Golder Associates <br />
The URL can be used to link to this page
Your browser does not support the video tag.