My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2003-07-11_REVISION - M1980244
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1980244
>
2003-07-11_REVISION - M1980244
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 5:49:50 PM
Creation date
11/21/2007 1:19:51 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
Revision
Doc Date
7/11/2003
Doc Name
Phase IV PSSA Area Cert Report
From
DMG
To
Cripple Creek & Victor Gold
Type & Sequence
AM8
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
June 24, 2003 -23- 003-2203.7 <br />. • Soil description (ASTM D2488); and <br />• Bulk specific gravity (ASTM C 127). <br />Golder conducted appropriate tests as required by the specifications for UF, SSF, FSB, LDF, <br />Subgrade Structural Fill, SF, SLF, BF, LVSCF, DCF, and SDCF. <br />The laboratory test results are summarized in Tables 5 through 16 and presented in Appendix I. <br />4.1.1 Grain Size Distribution <br />Golder analyzed the grain size distribution (gradation) of samples of UF, SSF, FSB, LDF, SF, SLF, <br />BF, LVSCF, DCF, and SDCF. The results of gradation analyses are presented in Appendix I-1 and <br />summarized in Tables 5 through 14. <br />Golder performed one CQA gradation of UF. The testing frequency (approximately one test per <br />1,659 cubic yards) exceeded the minimum specified testing frequency of one test per 5,000 cubic <br />. yards. The CQA gradation of OF met project specifications. The OF CQA gradation results are <br />presented in Appendix I-1 and summarized in Table 5. <br />Golder performed one CQA gradation of the SSE The testing frequency (approximately one test per <br />1,297 cubic yards) exceeded the minimum specified testing frequency of one test per 50,000 cubic <br />yards. The CQA gradations of SSF met project specifications. The SSF CQA gradation results are <br />presented in Appendix I-I and summarized in Table 6. <br />Golder performed three CQA gradations of LDF. The testing frequency (approximately one test per <br />34 cubic yards} exceeded the minimum specified testing frequency of one test per 10,000 cubic yards. <br />The CQA gradation of LDF met project specifications. The LDF CQA gradation results are <br />presented in Appendix I-1 and summarized in Table 7. <br />Golder performed four CQA gradations of SF. The testing frequency (approximately one test per <br />47,341 cubic yards) exceeded the minimum specified testing frequency of one test per 50,000 cubic <br />yards. The CQA gradations performed on SF met project specifications. The SF CQA gadation <br />. results are presented in Appendix I-I and summarized in Table 8. <br />r.~oouzos~aaav,acenvssposaa~oo3zzai.waa.o~.wx~p.a« CaOI(I@r ASSOC18t@S <br />