AS BUILT CERTIFICATIONS LIVESTOCK WATER TANKS
From
CYPRUS YAMPA VALLEY
To
DMG
Permit Index Doc Type
PROF POND CERTIFICATIONS
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
appear to meet the 3:1 requirement. <br />• 51W-A -- The elevation of the spillway crest needs to be reduced by <br />at least 3.64 feet. This modification will also correct the <br />inadequate residual freeboard at peak flow that currently exists. <br />The spillway needs to be extended 20 feet below the toe of the dam <br />and this extension will require erosion control material. The <br />spillway invert will also requires erosion control material but <br />this pond already has riprap at this point. All side slopes of this <br />pond appear to meet the 3:1 requirement. <br />51W-B -- The elevation of the spillway crest needs to be reduced by <br />at least 3.37 feet. This modification will also correct the <br />inadequate residual freeboard at peak flow that currently exists. <br />The spillway needs to be extended 20 feet below the toe of the dam <br />and this extension will require erosion control material. The <br />invert also requires erosion control material but this pond already <br />has riprap at this point. All side slopes of this pond appear to <br />meet the 3:1 requirement. <br />61-A -- The elevation of the spillway crest needs to be reduced by <br />at least 1.23 feet. The spillway needs to be extended 20 feet below <br />the toe of the dam and this extension requires erosion control <br />material. The east side slope of this pond also need repaired as it <br />is currently 2.75:1. <br />• 61-B -- The elevation of the spillway crest needs to be reduced by <br />at least 1.36 feet. This modification will also correct the <br />inadequate residual freeboard at peak flow that currently exists. <br />While the spillway for this pond does extend 20 feet below the toe <br />of the dam, this extension will require erosion control material. <br />The spillway invert also requires erosion control material but this <br />pond already has riprap at this point. All side slopes of this pond <br />appear to meet the 3:1 requirement. <br />61-C -- The spillway needs to be extended 20 feet below the toe of <br />the dam and this extension will require erosion control material. <br />The east side slope of this pond is 2.7:1 and will require repair. <br />While extending the spillway, the spillway crest elevation should <br />be reduced by at least 0.25 feet to insure the 4 foot requirement <br />is satisfied. <br />61-D --The elevation of the spillway crest needs to be reduced by <br />at least 2.07 feet. This modification will correct the inadequate <br />residual freeboard at peak flow that currently exists. The spillway <br />needs to be extended 20 feet below the toe of the dam and this <br />extension will require erosion control material. <br />2-A -- The elevation of the spillway crest needs to be reduced by <br />at least 1.02 feet. The spillway needs to be extended 20 feet below <br />the toe of the dam and this extension will require erosion control <br />material. While the majority of the side slopes meet the <br />• requirement of 3:1, the material from the spillway modification <br />should be used to repair the side slopes on the southeast side of <br />
The URL can be used to link to this page
Your browser does not support the video tag.