Newmont‐Cripple Creek & Victor Gold Mine  <br />Technical Specification No. 02200 EARTHWORKS  <br />VLF2 Phase 3  <br />Project No.475.0106.049  <br />August 27, 2021  <br />  <br />  <br />  <br />Technical Specification No. 02200 Earthworks    Page 18  <br />9. CONTRACTOR shall verify the final thickness of Drain Cover Fill to determine  <br />compliance with this SPECIFICATION. CONTRACTOR shall record verification location,  <br />elevation, and thickness.  CQA MONITOR shall witness all verification measurements.  <br />CONTRACTOR will submit a method of verifying Drain Cover Fill depth to MANAGER  <br />for approval.  Areas with deficient thickness shall be reworked by CONTRACTOR, until  <br />acceptable measurements are obtained. If MANAGER or CERTIFYING ENGINEER  <br />suspects the occurrence of any damage to the underlying geosynthetics, MANAGER  <br />will instruct CONTRACTOR to remove Drain Cover Fill to expose the geosynthetics.  <br />CONTRACTOR shall uncover, repair any observed damage of the underlying  <br />geosynthetics, in accordance with the repair requirements of Sections 02776 and  <br />02777 of the SPECIFICATIONS and recover, at no cost to CC&V.  <br />10. CONTRACTOR will provide adequate illumination as approved by MANAGER, if Drain  <br />Cover Fill placement is carried out at night. A minimum of 2‐foot candles measured  <br />at the synthetic liner shall be used when Drain Cover Fill placement is carried out at  <br />night.  <br />I. Select Drain Cover Fill  <br />1. Select Drain Cover Fill shall be placed around the PSSA Riser Pipes as shown on the     <br />drawings.   <br />2. CONTRACTOR shall place Select Drain Cover Fill in maximum 24‐inch loose lifts  <br />around the PSSA Riser Pipes. The fill elevation shall always rise evenly around the  <br />pipe.  <br />3. CONTRACTOR will not allow mobile heavy equipment to contact the PSSA Riser Pipe  <br />during fill placement.  <br />4. CONTRACTOR shall place Crushed Ore, or an equivalent material approved by the  <br />CERTIFYING ENGINEER and MANAGER around the limits of the Select Drain Cover  <br />Fill placement as the elevation of the Select Drain Cover Fill rises.   <br />5. Select Drain Cover Fill is to remain loose and free draining around the PSSA Riser Pipe  <br />Louvered Screen. Any material that is not loose around the screen will be scarified  <br />and made loose before the placement of the next lift of material.   <br />6. CONTRACTOR shall constantly monitor the plumb of the PSSA Riser Pipes during  <br />Select Drain Cover Fill placement. Any corrections required to maintain the plumb of  <br />the PSSA Riser Pipes will be done so at no cost to CC&V.  <br />J. Pipe Bedding Material  <br />1. Pipe bedding material shall be placed around the CSP as shown on the drawings.  <br />2. For piping external to the valley leach facility, CONTRACTOR shall compact the Pipe  <br />Bedding Material requiring compaction to at least 95 percent of the maximum dry