My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2025-01-27_REVISION - M1980244 (4)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1980244
>
2025-01-27_REVISION - M1980244 (4)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/28/2025 1:09:23 PM
Creation date
1/28/2025 11:37:46 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
Revision
Doc Date
1/27/2025
Doc Name Note
07 Appendix C
Doc Name
Request for Technical Revision
From
CC&V
To
DRMS
Type & Sequence
TR146
Email Name
ERR
ZTT
LJW
BEH
JPL
HR1
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
138
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Newmont‐Cripple Creek & Victor Gold Mine <br />Technical Specification No. 02200 EARTHWORKS <br />VLF2 Phase 3 <br />Project No.475.0106.049 <br />August 27, 2021 <br /> <br /> <br /> <br />Technical Specification No. 02200 Earthworks Page 16 <br />surface to the satisfaction of MANAGER and CERTIFYING ENGINEER, at no additional <br />cost to CC&V. <br />14. CONTRACTOR shall maintain the Soil Liner Fill surface in a condition suitable for <br />geomembrane installation as specified in these SPECIFICATIONS and in the CQA Plan <br />until the surface is covered. CONTRACTOR shall repair all weather related damage to <br />Soil Liner Fill surfaces or other portions of the Work that have or have not been <br />covered by geomembrane, at no additional cost to CC&V. If any moisture is allowed <br />to collect under the geomembrane prior to or after final seaming and softens the Soil <br />Liner Fill, the geomembrane shall be removed and CONTRACTOR shall recondition <br />and recompact the Soil Liner Fill to meet all placement and trimming <br />SPECIFICATIONS, at no additional cost to CC&V. <br />15. CONTRACTOR shall remove all hubs and survey stakes in the Soil Liner Fill and backfill <br />all holes with MANAGER and CERTIFYING ENGINEER approved moisture‐ <br />conditioned Soil Liner Fill or bentonite. Compact with a Proctor hammer or other <br />suitable device that will achieve a kneading type of compaction and will achieve the <br />required density. <br />16. CONTRACTOR shall verify the final thickness of Soil Liner Fill to determine compliance <br />with this SPECIFICATION. Thickness verification shall be performed at a minimum <br />frequency of two measurements per acre using a soil‐coring device, unless directed <br />otherwise by MANAGER. CONTRACTOR shall record as part of the as‐built <br />documentation the location, elevation, and thickness of each Soil Liner Fill <br />verification test. CQA MONITOR will witness all verification measurements. <br />CONTRACTOR shall backfill all holes with MANAGER and CERTIFYING ENGINEER <br />approved moisture‐ conditioned Soil Liner Fill compacted with a Proctor hammer or <br />other suitable device that will achieve a kneading type of compaction and will achieve <br />the required density, or bentonite. Areas with deficiencies shall be reworked by <br />CONTRACTOR, until acceptable measurements are obtained at no additional cost to <br />CC&V. <br />17. If tests indicate the Work does not meet the requirements of the SPECIFICATIONS, <br />MANAGER and CERTIFYING ENGINEER will establish the extent of the <br />nonconforming area. The nonconforming area shall be re‐worked by CONTRACTOR <br />until acceptable test results are obtained at no additional cost to CC&V <br />18. Prior to any geosynthetics being placed on Soil Liner Fill, the area will be tested by <br />CQA MONITOR. No geosynthetics will be allowed to be placed on frozen material, as <br />defined in Section 3.6.A.10, without the area in question being retested by the CQA <br />MONITOR. <br />H. Drain Cover Fill <br />1. Drain Cover Fill shall be placed over the geomembrane in the locations shown on the <br />DRAWINGS.
The URL can be used to link to this page
Your browser does not support the video tag.