My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2021-12-22_REVISION - M2012032
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M2012032
>
2021-12-22_REVISION - M2012032
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2024 6:06:22 PM
Creation date
1/3/2022 9:11:25 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2012032
IBM Index Class Name
Revision
Doc Date
12/22/2021
Doc Name Note
Request for Tailings Placement for the Revenue Mine
Doc Name
Request for Tailings Placement for the Revenue Mine
From
Ouray Silver Mines, Inc
To
DRMS
Type & Sequence
TR15
Email Name
LJW
THM
ACY
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AUZ Laboratories, Inc. I • • - • - • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 O - • • <br /> Ouray Silver Mines ACZ Project ID: L69171 <br /> ACZ ID WORKNUM PARAMETER METHOD QUA <br /> L DESCRIPTION <br /> WG531044 Fluoride(1312 DI) SM450OF-C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG530612 Hydroxide as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature <br /> WG530712 Iron(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG530915 Lead(1312) M6020B ICP-MS RD For a solid matrix,the duplicate RPD(spike or matrix) <br /> exceeded the control limit,which is attributable to the non- <br /> homogeneity of the sample. <br /> M6020B ICP-MS ZG The ICP or ICP-MS Serial Dilution was not used for data <br /> validation because the sample concentration was less than <br /> 50 times the MDL <br /> WG530787 Lithium(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> Magnesium(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL). <br /> WG530915 Manganese(1312) M6020B ICP-MS ZH Serial Dilution exceeded the acceptance criteria Matrix <br /> interference[physical or chemical]is suspected <br /> WG530581 Mercury(1312) M7470A CVAA Q6 Sample was received above recommended temperature <br /> M7470A CVAA RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG530915 Molybdenum(1312) M6020B ICP-MS ZG The ICP or ICP-MS Serial Dilution was not used for data <br /> validation because the sample concentration was less than <br /> 50 times the MDL <br /> Nickel(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> WG530636 Nitrate/Nitrite as N(1312-DI) M353 2-Automated Cadmium HD Analysis is outside the intended scope of the method,which <br /> Reduction does not provide hold time information for sod extracts No <br /> hold time is observed for collection to extraction The <br /> referenced method hold time is observed for extraction-to- <br /> analysis <br /> M353 2-Automated Cadmium Q6 Sample was received above recommended temperature <br /> Reduction <br /> M353 2-Automated Cadmium RA Relative Percent Difference(RPD)was not used for data <br /> Reduction validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> Nitrite as N(1312-DI) M353.2-Automated Cadmium HD Analysis is outside the intended scope of the method,which <br /> Reduction does not provide hold time information for soil extracts No <br /> hold time is observed for collection to extraction The <br /> referenced method hold time is observed for extraction-to- <br /> analysis <br /> M353.2-Automated Cadmium Q6 Sample was received above recommended temperature. <br /> Reduction <br /> M353 2-Automated Cadmium RA Relative Percent Difference(RPD)was not used for data <br /> Reduction validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG531648 Nitrogen,ammonia(1312-DI) M350 1 Auto Salicylate w/gas HD Analysis is outside the intended scope of the method,which <br /> diffusion does not provide hold time information for sod extracts No <br /> hold time is observed for collection to extraction The <br /> referenced method hold time is observed for extraction-to- <br /> analysis <br /> M350 1 Auto Salicylate w/gas Q6 Sample was received above recommended temperature. <br /> diffusion <br /> WG530634 Phosphorus,ortho dissolved(1312-DI) M365 1-Automated Ascorbic HD Analysis is outside the intended scope of the method,which <br /> does not provide hold time information for soil extracts. No <br /> hold time is observed for collection to extraction The <br /> referenced method hold time is observed for extraction-to- <br /> analysis <br /> M365 1-Automated Ascorbic RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> REPAD.15.06 05.01 <br /> L691 71-21 1 2031 01 8 Page 20 of 25 <br />
The URL can be used to link to this page
Your browser does not support the video tag.