My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2021-12-22_REVISION - M2012032
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M2012032
>
2021-12-22_REVISION - M2012032
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2024 6:06:22 PM
Creation date
1/3/2022 9:11:25 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2012032
IBM Index Class Name
Revision
Doc Date
12/22/2021
Doc Name Note
Request for Tailings Placement for the Revenue Mine
Doc Name
Request for Tailings Placement for the Revenue Mine
From
Ouray Silver Mines, Inc
To
DRMS
Type & Sequence
TR15
Email Name
LJW
THM
ACY
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACZ Laboratories, Inc. • • - • - • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 WOM Hm".?- • • <br /> Ouray Silver Mines ACZ Project ID: L69171 <br /> METHOD OCRIPTION <br /> WG531173 Phosphorus,Total(1312-DI) M365 1-Auto Ascorbic Acid HD Analysis is outside the intended scope of the method,which <br /> (digest) does not provide hold time information for soil extracts No <br /> hold time is observed for collection to extraction The <br /> referenced method hold time is observed for extraction-to- <br /> analysis <br /> M365.1-Auto Ascorbic Acid RA Relative Percent Difference(RPD)was not used for data <br /> (digest) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG530712 Potassium(1312) M6010D ICP ZG The ICP or ICP-MS Serial Dilution was not used for data <br /> validation because the sample concentration was less than <br /> 50 times the MDL <br /> WG530627 Residue,Filterable(TDS)@180C(1312) SM2540C N1 See Case Narrative <br /> SM2540C RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG531061 Residue,Non-Filter(TSS)@180C(1312-SM2540D RA Relative Percent Difference(RPD)was not used for data <br /> DI) validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> SM2540D Z3 Sample volume yielded a residue less than 2 5 mg <br /> WG530915 Selenium(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> Silver(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG530712 Sodium(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG532073 Sulfate(1312-DI) M300 0-Ion Chromatography HD Analysis is outside the intended scope of the method,which <br /> does not provide hold time information for soil extracts No <br /> hold time is observed for collection to extraction The <br /> referenced method hold time is observed for extraction-to- <br /> analysis. <br /> WG532185 Sulfur Organic Residual M600/2-78-054 3 2 4-MOD RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> Sulfur Pyritic Sulfide M600/2-78-054 3 2 4-MOD RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> Sulfur Sulfate M600/2-78-054 3 2 4-MOD RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL). <br /> Sulfur Total M600/2-78-054 3.2 4-MOD RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG530915 Thallium(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG530712 Tin(1312) M6010D ICP RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG530612 Total Alkalinity SM2320B-Titration Q6 Sample was received above recommended temperature <br /> WG532185 Total Sulfur minus Sulfate M600/2-78-054 3 2 4-MOD RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG530915 Uranium(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> Vanadium(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> Zinc(1312) M6020B ICP-MS RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> REPAD.15.06 05.01 <br /> L691 71-21 1 2031 01 8 Page 21 of 25 <br />
The URL can be used to link to this page
Your browser does not support the video tag.