Laserfiche WebLink
ACZ Laboratories, Inc. ' <br />2773 Downhill Drive Steamboat Springs CO 80487 (800) 334-5493 <br />Ouray Silver Mines Ai Project ID. L69169 <br />L69169-02 NG530787 Aluminum (1312) N16010D ICP <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the concentration of the duplicated <br />sample is too low for accurate evaluation i< 1 Ox MDL) <br />VVG530915 Antimony (1312) N16020B ICP-MS <br />M3 The spike recovery value is unusable since the analyte <br />concentration in the sample is disoroport onate to the soike <br />level The recovery of the associated control sample ;LCS <br />or LFB) was acceptable <br />M6020B ICP-MS <br />ZG The ICP or ICP-MS Serial Dilution was not used for data <br />validation because the sample concentration was less than <br />50 times the MDL <br />Arsenic (1312) N16020B ICP-MS <br />ZH Serial Dilution exceeded the acceptance criteria Matrix <br />interference [physical or chemical] is suspected <br />Barium (1312) M6020B ICP-MS <br />ZH Serial Dilution exceeded the acceptance criteria Matrix <br />interference [physical or chemical] is suspected <br />Beryllvm (1312) M6020B ICP-MS <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the concentration of the duplicated <br />sample is too low for accurate evaluation (< 1 Ox MDL) <br />W G530612 Bicaroonate as CaCO3 SM2320B - Titration <br />Q6 Sample was received above recommended temperature <br />WG530712 Boron (1312) N16010D ICP <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the concentration of the duplicated <br />samoie is too low for accurate evaluation (< 1 Ox MDL) <br />WG531493 Bromide (1312-DI) M300 0 - Ion Chromatography <br />HD Analysis is outside the intended scope of the method, which <br />does not orovide hold time information for sod extracts No <br />hold Lme s observed for collection to extraction The <br />referenced method hold time is observed for extraction -to - <br />analysis <br />M300 0 - Ion Chromatography <br />M2 Matrix spike recovery was low the recovery of the <br />associated control sample (LCS or LFB) was acceptable <br />M300 0 - Ion Chromatography <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the concentration of the duplicated <br />sample is too low for accurate evaluation (< 1 Ox MDL) <br />W G530915 Cadmium (1312) M6020B ICP-MS <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the concentration of the duplicated <br />sample is too low for accurate evaluation (< 1 Ox MDL) <br />WG531038 Carbon, total organic (TOC) (1312-DI) SM5310B <br />HD Analysis is outside the intended scope of the method, which <br />does not provide hold time information for soil extracts No <br />hold time is observed for collection to extraction The <br />referenced method hold time is observed for extraction -to - <br />analysis <br />SM5310B <br />06 Sample was received above recommended temperature <br />SM5310B <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the concentration of the duplicated <br />sample is too low for accurate evaluation (< 1 Ox MDL) <br />W G530612 Carbonate as CaCO3 SM2320B - Titration <br />06 Sample was received above recommended temperature <br />W G531493 Chloride t1312-DI) M300 0 - Ion Chromatography <br />HD Analysis ;s outside the intended scope of the method, which <br />does not orovide hold time information for soil extracts No <br />hold time is observed for collection to extraction The <br />referenced method hold time is observed for extraction -to - <br />analysis <br />M300 0 - Ion Chromatography <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the concentration of the duplicated <br />sample s too low for accurate evaluation (< 1 Ox MDL) <br />VVG530915 Chromium ;1312) M6020B ICP-MS <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the concentration of the duplicated <br />sample is too low for accurate evaluation (< 1 Ox MDL) <br />Cobalt (1312) M6020B ICP-MS <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the concentration of the duplicated <br />sample is too low for accurate evaluation (< 10x MDL) <br />WG530612 Conductivity @25C (1312-DI) SM25106 <br />Q6 Sample was received above recommended temperature <br />WG530915 Copper (1312) M6020B ICP-MS <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the concentration of the duplicated <br />sample is too low for accurate evaluation (< 1 Ox MDL) <br />WG531044 Fluoride (1312 DI) SM450OF-C <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the concentration of the duplicated <br />sample is too low for accurate evaluation (< 10x MDL) <br />W G530612 Hydroxide as CaCO3 SM2320B - Titration <br />06 Sample was received above recommended temperature <br />REPAD 15 06 05 01 <br />L69169-21 1 1231041 Page 22 of 28 <br />