My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-10-22_REVISION - M2008078 (14)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M2008078
>
2018-10-22_REVISION - M2008078 (14)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/4/2025 6:22:02 AM
Creation date
10/23/2018 10:01:47 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2008078
IBM Index Class Name
Revision
Doc Date
10/22/2018
Doc Name Note
Part 1 of 6
Doc Name
Request For Amendment To Permit
From
Prowers Aggregate Operators, LLC
To
DRMS
Type & Sequence
AM1
Email Name
AME
MAC
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Stormwater discharges shall be monitored when they are occurring. Samples shall be collected <br /> at Discharge Point 001 for testing. No discharges will occur at Discharge Point 002. The <br /> following table summarizes the monitoring requirements for Discharge Point 001. <br /> Discharge Limitations <br /> Parameter Units Maximum Concentrations Monitoring Sample <br /> 30-Day 7-Day Daily Max 2 year Frequency Type <br /> Average Avera a Average <br /> Continuous/ Recorder/In- <br /> Flow MGD 2.16 NA Report NA Instantaneous, situ <br /> Monthly <br /> pH, (Minimum- s.u. NA NA 6.5-9.0 NA 2x/month Grab <br /> Maximum <br /> Total Suspended Mg/I 30 45 NA NA 2x/month Grab <br /> Solids <br /> Oil and Grease NA NA NA NA 2x/month Visual <br /> Visual <br /> Oil and Grease mg/I NA NA 10 NA If visual sheen Grab <br /> is observed <br /> Site Specific Limitations <br /> Report Continuous/ <br /> Total Flow MG Qrtr Total NA NA NA Instantaneous, Calculated <br /> Monthly <br /> Electrical ds/m Report NA NA NA Quarterly Grab <br /> Conductivity <br /> Manganese, ug/I Report NA Report NA 2x/month Grab <br /> Dissolved <br /> Selenium, <br /> Potentially ug/I Report NA Report NA 2x/month Grab <br /> Dissolved <br /> Total Recoverable ug/I Report NA Report NA 2x/month Grab <br /> Uranium <br /> pH sampling and testing will be done onsite with a portable pH measuring test kit. Grab samples <br /> for Total Suspended Solids, Oil and Grease, Electrical Conductivity, Dissolved Manganese, <br /> Potentially Dissolved Selenium, and Total Recoverable Uranium shall be taken directly from the <br /> Discharge Point 001 pipe discharge flow in containers provided by the laboratory using the <br /> following procedure: <br /> • It is recommended that rubber gloves be worn during sampling to avoid skin contact with <br /> the preservatives. Should skin or clothing contact any preservative flush the area <br /> thoroughly with water. <br /> • Each sample container will have a label that identifies the test to be performed and the <br /> preservative present, if any. <br /> • Complete the sample label prior to placing on the container. Use a waterproof pen. <br /> • Fill the sample container slowly to -1" below the top to reduce the headspace present. <br /> Be careful not to overfill and wash out the preservative. If the preservative is washed out, <br /> proceed with filling the container, however, note that the preservative was washed out <br /> on the sample label. <br /> • Filling the container with less than 1" headspace could result in bottle breakage as the <br /> sample expands. <br /> • Repeat for each container provided for each sample location. It is important that all <br /> containers be filled and properly labeled. <br /> • Samples should be placed in a cooler, packed with ice (in Ziploc bags to avoid leaking), <br /> and ship via overnight service to the laboratory for testing. <br /> 7 <br />