Laserfiche WebLink
AUZ Laboratories, Inc. • - - • . • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 - r • , <br /> Golder Associates ACZ Project ID: L37566 <br /> r •- METER METHOD <br /> L37566-04 NG424199 Bicarbonate as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature <br /> Carbonate as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature , <br /> WG425180 Chloride M300 0-Ion Chromatography Q6 Sample was received above recommended temperature <br /> M300 0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) ' <br /> WG424199 Hydroxide as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature <br /> pH SM4500H+B Q6 Sample was received above recommended temperature <br /> pH measured at SM4500H+B Q6 Sample was received above recommended temperature <br /> WG424116 Residue,Filterable(TDS)@180C SM2540C Q6 Sample was received above recommended temperature ' <br /> WG425180 Sulfate M300 0-Ion Chromatography DC Sample required dilution Non-target analyte exceeded <br /> calibration range <br /> M300.0-Ion Chromatography Q6 Sample was received above recommended temperature <br /> WG424199 Total Alkalinity SM2320B-Titration Q6 Sample was received above recommended temperature <br /> L37566-05 NG424199 Bicarbonate as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature <br /> Carbonate as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature <br /> WG425180 Chloride M300 0-Ion Chromatography DC Sample required dilution Non-target analyte exceeded <br /> calibration range <br /> M300 0-Ion Chromatography Q6 Sample was received above recommended temperature <br /> M300 0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data ' <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG424199 Hydroxide as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature <br /> pH SM4500H+B Q6 Sample was received above recommended temperature ' <br /> pH measured at SM4500H+B Q6 Sample was received above recommended temperature <br /> WG424116 Residue,Filterable(TDS)@180C SM2540C Q6 Sample was received above recommended temperature <br /> WG425180 Sulfate M300 0-Ion Chromatography Q6 Sample was received above recommended temperature <br /> WG424199 Total Alkalinity SM2320B-Titration Q6 Sample was received above recommended temperature ' <br /> L37566-06 NG424199 Bicarbonate as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature <br /> Carbonate as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature <br /> WG425180 Chloride M300 0-Ion Chromatography Q6 Sample was received above recommended temperature <br /> M300 0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG424199 Hydroxide as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature <br /> pH SM4500H+B Q6 Sample was received above recommended temperature <br /> SM4500H+B ZW Method deviation The sample was centrifuged prior to <br /> analysis due to high solid content , <br /> pH measured at SM4500H+B Q6 Sample was received above recommended temperature <br /> WG424116 Residue,Filterable(TDS)@180C SM2540C Q6 Sample was received above recommended temperature <br /> WG425180 Sulfate M300 0-Ion Chromatography DC Sample required dilution Non-target analyte exceeded <br /> calibration range ' <br /> M300 0-Ion Chromatography Q6 Sample was received above recommended temperature <br /> WG424199 Total Alkalinity SM2320B-Titration Q6 Sample was received above recommended temperature <br /> SM2320B-Titration ZW Method deviation The sample was centrifuged prior to <br /> analysis due to high solid content ' <br /> REPAD.15 06.05.01 <br /> L37566-1706221642 Page 16 of 23 , <br />