My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-08-04_HYDROLOGY - M1977348
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977348
>
2017-08-04_HYDROLOGY - M1977348
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2020 2:07:49 PM
Creation date
8/7/2017 8:30:51 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977348
IBM Index Class Name
HYDROLOGY
Doc Date
8/4/2017
Doc Name
Water Monitoring - Groundwater
From
Golder Associates
To
DRMS
Email Name
AME
Media Type
D
Archive
No
Tags
DRMS Re-OCR
Description:
Signifies Re-OCR Process Performed
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AUZ Laboratories, Inc. • - - • . • <br /> 2773 Downhill Drive Steamboat Springs, CO 80487 (800)334-5493 - r • , <br /> Golder Associates ACZ Project ID: L37566 <br /> r •- METER METHOD <br /> L37566-04 NG424199 Bicarbonate as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature <br /> Carbonate as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature , <br /> WG425180 Chloride M300 0-Ion Chromatography Q6 Sample was received above recommended temperature <br /> M300 0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) ' <br /> WG424199 Hydroxide as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature <br /> pH SM4500H+B Q6 Sample was received above recommended temperature <br /> pH measured at SM4500H+B Q6 Sample was received above recommended temperature <br /> WG424116 Residue,Filterable(TDS)@180C SM2540C Q6 Sample was received above recommended temperature ' <br /> WG425180 Sulfate M300 0-Ion Chromatography DC Sample required dilution Non-target analyte exceeded <br /> calibration range <br /> M300.0-Ion Chromatography Q6 Sample was received above recommended temperature <br /> WG424199 Total Alkalinity SM2320B-Titration Q6 Sample was received above recommended temperature <br /> L37566-05 NG424199 Bicarbonate as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature <br /> Carbonate as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature <br /> WG425180 Chloride M300 0-Ion Chromatography DC Sample required dilution Non-target analyte exceeded <br /> calibration range <br /> M300 0-Ion Chromatography Q6 Sample was received above recommended temperature <br /> M300 0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data ' <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<10x MDL) <br /> WG424199 Hydroxide as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature <br /> pH SM4500H+B Q6 Sample was received above recommended temperature ' <br /> pH measured at SM4500H+B Q6 Sample was received above recommended temperature <br /> WG424116 Residue,Filterable(TDS)@180C SM2540C Q6 Sample was received above recommended temperature <br /> WG425180 Sulfate M300 0-Ion Chromatography Q6 Sample was received above recommended temperature <br /> WG424199 Total Alkalinity SM2320B-Titration Q6 Sample was received above recommended temperature ' <br /> L37566-06 NG424199 Bicarbonate as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature <br /> Carbonate as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature <br /> WG425180 Chloride M300 0-Ion Chromatography Q6 Sample was received above recommended temperature <br /> M300 0-Ion Chromatography RA Relative Percent Difference(RPD)was not used for data <br /> validation because the concentration of the duplicated <br /> sample is too low for accurate evaluation(<1 Ox MDL) <br /> WG424199 Hydroxide as CaCO3 SM2320B-Titration Q6 Sample was received above recommended temperature <br /> pH SM4500H+B Q6 Sample was received above recommended temperature <br /> SM4500H+B ZW Method deviation The sample was centrifuged prior to <br /> analysis due to high solid content , <br /> pH measured at SM4500H+B Q6 Sample was received above recommended temperature <br /> WG424116 Residue,Filterable(TDS)@180C SM2540C Q6 Sample was received above recommended temperature <br /> WG425180 Sulfate M300 0-Ion Chromatography DC Sample required dilution Non-target analyte exceeded <br /> calibration range ' <br /> M300 0-Ion Chromatography Q6 Sample was received above recommended temperature <br /> WG424199 Total Alkalinity SM2320B-Titration Q6 Sample was received above recommended temperature <br /> SM2320B-Titration ZW Method deviation The sample was centrifuged prior to <br /> analysis due to high solid content ' <br /> REPAD.15 06.05.01 <br /> L37566-1706221642 Page 16 of 23 , <br />
The URL can be used to link to this page
Your browser does not support the video tag.