1.6 INSTALLATION -ELECTRICAL <br />The retort has been pre -wired at the factory <br />Wiring Diagram for details. Ensure that <br />adequately grounded. <br />Refer to the Electrical Schematic and Field <br />the disconnect switch and the retort are <br />Connect the main power supply (480/3/60) to the input lugs located inside the SCR/Control <br />Panel. <br />The heating elements have all been wired for a balanced and equal load on each phase. <br />After the retort is installed and before connection to the SCR drive, check the following: <br />1. Check each heating element for a dead short circuit to ground.Only a high <br />resistance should be indicated (this is due to normal leakage through the refractory) <br />or if the refractory isslightly damp there may be a small voltage produced between <br />the heating elements and equipment ground which also proves the absence of any <br />short-circuits to ground. <br />2. Check for a balanced resistance between all three phases of thesplitter. <br />3. See the Equipment Data Sheet in Section VI for the line -to -line resistance and line <br />current values. <br />4. Some thermocouples and temperature transmittershave been shipped separately. <br />Install and wire the temperature transmitters as shown on the Electrical Schematic. <br />5. The warning beacon light on top of the control panel has been disconnected for <br />shipping. Replace the light bulb and reconnect as shown on the Electrical Schematic. <br />11