Technical Memorandum  <br />Newmont CC&V Gold Mine  <br />East Cresson Overburden Storage Area Stability Review/Update  <br />NewFields Job No. 475.0106.005  <br />9 December 2016  <br />  <br />  <br />Page 5  <br /> Overburden:  Overburden material in the ECOSA is essentially rockfill from the pits with no  <br />economic value.  As such, the engineering properties are similar to that of the ore that has  <br />been studied throughout the project history and modeled with a 39 or 40 degree friction  <br />angle.  In agreement with older designs, the initial evaluation of the ECOSA considered a  <br />friction angle of 39 degrees (Adrian Brown, 2012).  Based on the project history and new  <br />laboratory test data (measured friction angle of 41 degrees), the continued use of a 39  <br />degree friction angle to represent the strength of the overburden was deemed reasonable  <br />and applied in the current evaluation.     <br /> Colluvium:  Strength parameters for the colluvium foundation was based on the recent  <br />laboratory test data and existing data from around the site for unconsolidated foundation  <br />materials.    Adrian  Brown  (2012)  characterized  the  strength  of  the  colluvium  under  the  <br />ECOSA using an empirical relationship between shear strength, liquid limit and clay fraction  <br />of the material.  Based on visual observation of colluvium and recent test data, this value is  <br />too conservative for a coarse‐gravel with minimal fines.  The current evaluation uses an  <br />average value between the recent laboratory data and that utilized by Adrian Brown (35  <br />degree and no cohesion).  As some of the fines within the colluvium are fine‐grained, the  <br />strength  was  reduced  by  20  percent  for  the  pseudostatic  evaluation  to  account  for  <br />development of excess pore pressure.    <br /> Bedrock:  The dominant rock type underlying the facility is Tertiary phonolites.  The unit  <br />weight and strength for bedrock was developed from data presented by Call & Nicholas  <br />(2015) for this material type and a poor to fair rock quality designation (40 – 60%).  The  <br />associated unit weight, φ and cohesion values are 153 pcf, 34.5 degrees and 20,000 psf,  <br />respectively.    <br /> Stability Evaluation Results 3.4 <br />The stability analyses resulted in acceptable minimum FOS values for both static and pseudo‐ <br />static conditions, as show in Table 2.2.  The output graphics from the stability models are  <br />included as Attachment C.    <br />  <br />  <br />  <br />  <br />  <br />  <br />  <br />