Newmont‐Cripple Creek & Victor Gold Mine  <br />Technical Specification No. 01400‐2.DOCX  <br />Squaw Gulch VLF  <br />Project No.475.0106.006  <br />August 25, 2016  <br />  <br />  <br />  <br />Page 4  <br />must  verify prior to construction that the MANUFACTURER can produce material that meets  <br />the requirements outlined in project SPECIFICATIONS.  <br />2.7. Geosynthetics Installation Contractor  <br />The  Geosynthetics  Installation  Contractor,  also  referred  to  as the  "CONTRACTOR"  or  <br />"INSTALLER", is responsible for installation of the geosynthetic components, as outlined in the  <br />project SPECIFICATIONS.  <br />The INSTALLER must meet the requirements outlined in the project SPECIFICATIONS.  <br />The INSTALLER will be responsible for storage, handling, deploying, temporary geomembrane  <br />anchoring, seaming, repairs and non‐destructive testing, in accordance with the project plans,  <br />SPECIFICATIONS  and  the  Installer’s  internal  quality  control  program.  It  is  the  Installer’s  <br />responsibility to see that all submittals are received as outlined in the project SPECIFICATIONS.  <br />2.8. Earthworks Contractor  <br />The  Earthworks  Contractor,  also  referred  to  as  "CONTRACTOR"  is  responsible  for  proper  <br />delivery and placement of earthwork components as outlined in the project SPECIFICATIONS.    <br />3. PART 3: LINES OF COMMUNICATION  <br />The  CQA  Monitor  shall  be  capable  of  direct  communication  with  the MANAGER, DESIGN  <br />ENGINEER, CERTIFYING  ENGINEER and CONTRACTOR  at  all  times.  Deficiencies  that  can  be  <br />easily remedied, such as unsatisfactory test results, will be dealt with directly between the  <br />CQA Monitor, INSTALLER , and/or CONTRACTORS.  <br />If there is a disagreement among the DESIGN  ENGINEER, CERTIFYING  ENGINEER  and/or  <br />MANAGER that cannot be resolved among themselves, MANAGER shall present the matter to  <br />CC&V with MANAGER related recommendations and CC&V shall decide the matter with such  <br />decision being final.    <br />4. PART 4: DEFICIENCIES  <br />When  deficiencies (items  that do  not meet project requirements) are discovered, the CQA  <br />Monitor  shall immediately determine the nature and extent of the problem and notify the  <br />INSTALLER or CONTRACTOR. If unsatisfactory test results identify a deficiency, additional tests  <br />will be performed to define the extent of the deficient area.  <br />The INSTALLER or CONTRACTOR shall correct the deficiency to the satisfaction of the  CQA  <br />Monitor.  If  the CONTRACTOR  is  unable  to  correct  the  problem,  the  CQA  Monitor  will