Newmont‐Cripple Creek & Victor Gold Mine  <br />Technical Specification No. 01400.DOCX  <br />Squaw Gulch VLF  <br />Project No.475.0106.006  <br />August 25, 2016  <br />  <br />  <br />  <br />Page 4  <br />unsatisfactory  test  results,  will  be  dealt  with  directly  between  the  CQA  Monitor,  and  <br />CONTRACTOR.  The  CQA  Monitor  will  also  discuss  any  deficiencies  with  the CERTIFYING  <br />ENGINEER.  <br />If there is a disagreement among the DESIGN  ENGINEER,  CERTIFYING  ENGINEER, and/or  <br />MANAGER that cannot be resolved among themselves, MANAGER shall present the matter to  <br />CC&V with MANAGER related recommendations and CC&V shall decide the matter with such  <br />decision being final.  <br />4. PART 4: DEFICIENCIES  <br />When deficiencies (items that do not meet SPECIFICATIONS or DRAWINGS) are discovered, the  <br />CQA Monitor will immediately determine the nature and extent of the problem and notify the  <br />CONTRACTOR.  If  unsatisfactory  test  results  identify  a  deficiency,  additional  tests  will  be  <br />performed to define the extent of the deficient area.  <br />CONTRACTOR shall correct the deficiency to the satisfaction of the CQA Monitor.  If  <br />CONTRACTOR is unable to correct the problem, the CQA Monitor will notify MANAGER and  <br />CERTIFYING ENGINEER which will assist in problem resolution. If the solution involves a design  <br />revision, the DESIGN ENGINEER shall also be contacted.  <br />The CQA Monitor shall retest and the MANAGER and CERTIFYING ENGINEER shall approve the  <br />corrected deficiencies before any additional related work is performed by CONTRACTOR. All  <br />retests and related documentation shall be recorded by the CQA Monitor and included in the  <br />Construction Certification Report.    <br />5. PART 5: MEETINGS  <br />This  section  identifies  and  describes  the  meetings  to  be  held  during  the  course  of  the  <br />construction. Meetings shall be held in order to clearly define construction activities and goals  <br />in order to facilitate construction.  <br />5.1. Preconstruction Meeting  <br />MANAGER will hold a preconstruction meeting at the site prior to the start of construction.  <br />MANAGER, DESIGN   ENGINEER,   CERTIFYING   ENGINEER,   CQA   Monitor,   CONTRACTOR,    <br />and others designated by MANAGER shall attend this meeting. The purpose of this meeting will  <br />be to:  <br /> review the construction DRAWINGS, CQA Plan, and SPECIFICATIONS;  <br /> define the responsibilities of each party;  <br /> define lines of communication and authority;