Laserfiche WebLink
• Rat slab: up to 5' of concrete over bedrock — one row of #5 rebar <br />• Footers: 2436" footers I <br />■ Walls: 18" thick by 12' tall <br />■ Slab: 8" thick <br />• RCM50 Rustable metal siding and roofing <br />• In -Floor Radiant and Baseboard heating <br />• Spray Foam Insulation <br />• Propane Boiler Heat <br />• The filter building has filter presses for de <br />• Switch Gear Building <br />o 25' wide x 30' long x 17' high "at peak" <br />0 <br />i <br />ng the fine tailings prior to disposal. <br />Rat Slab and Monolithic /Grade Beam Foundation <br />• Rat Slab: up to 5' thick to bedrock <br />• Monolithic Slab: Grade beam: 18 "w x 30 "d <br />• Slab: 8" thick <br />RCM50 Rustable metal siding and roofing <br />No heat source <br />R -Max Rigid Foam Board and Spray Foam Insulation <br />The switch gear building has the transformers and switch gear that are used to <br />supply the voltage needed for all site uses I <br />• Thickener and Foundation <br />o 26' diameter x 8 ft high welded steel plate thic <br />r to be removed in sections <br />using cutting torches I <br />o Reinforced Concrete Slab Foundation (1692 sq. ft. in area) <br />Revenue Mine March 2015 L -5 <br />