Laserfiche WebLink
SECTION 03 60 00 <br />GROUTING <br />PART 1 GENERAL <br />1.1 SUMMARY <br />A. Section Includes: <br />1. Portland cement grout. <br />1.2 REFERENCES <br />A. American Concrete Institute: <br />I. ACI 301 - Specifications for Structural Concrete. <br />B. American Society of Testing and Materials: <br />1. ASTM C33 - Standard Specification for Concrete Aggregates. <br />2. ASTM C40 - Test Method for Organic Impurities in Fine Aggregates for <br />Concrete. <br />3. ASTM C 150 - Standard Specification for Portland Cement. <br />1.3 SUBMITTALS <br />A. Section 01 33 00 - Submittal Procedures: Requirements for submittals. <br />B. Product Data: Submit product data on grout. <br />1.4 SUSTAINABLE DESIGN SUBMITTALS — Not Used <br />1.5 QUALITY ASSURANCE <br />A. Visually inspect grout as it is delivered to site to determine if adequate slump is <br />maintained to allow for grout to be pumped into abandoned dewatering pipe. <br />1.6 DELIVERY, STORAGE, AND HANDLING <br />A. Grout to be delivered to site via mixer trucks. <br />B. ENVIRONMENTAL REQUIREMENTS — Not Used <br />PART 2 PRODUCTS <br />2.1 PORTLAND CEMENT GROUT MATERIALS <br />A. Portland Cement: ASTM C150, Type I and II. <br />NCCI Pit #1 Reservoir Liner - Technical Specifications Grouting <br />03 60 00 - 1 <br />