Laserfiche WebLink
14. Approved page 2.05 -13 identifies a section of Haul Road B located within the 100ft stream buffer <br />zone and the justification for a variance for the Haul Road being located within the buffer zone. <br />This information is not included on the proposed page 2.05 -13. Please include the approved <br />information discussing the justification for a portion on Haul Road B to be within the 100 ft <br />stream buffer zone. <br />15. In a comment letter dated May 8, 2014 the Colorado Division of Water Resources (DWR) states that <br />if the 13 identified stock water ponds are permanent or are proposed to be permanent, the DWR <br />recommends the owner of the ponds file for water rights and complete applications for the stock <br />tanks as Livestock Water Tanks. Please provide information as to the operators intention to file <br />for water rights or permitting the stock ponds as Livestock Water Tanks if the ponds are to <br />remain permanent. <br />16. Approved page 2.05 -96 includes text associated with hydrologic protection and reclamaton plans <br />that is omitted on the proposed page 2.05 -96. Please include all previously approved required <br />text. <br />17. Proposed page 2.05 -103 identifies structures and renewable resource lands identified in the area <br />above mine works. Per Rule 2.05.6(6)(a) the list of structures should include ALL structures and <br />renewable resource lands within the permit area and adjacent area and under Rule 2.05.6(6)(b) <br />state if the structures will be affected. Not included in the list of structures are water wells, <br />oil /gas sites, reservoirs, culverts, building (mine related private), pipelines, etc. Please provide <br />an accurate list of ALL structures above proposed mine works and state if the structures will be <br />affected. <br />18. Proposed Exhibit 2.05.6 -E4, Subterra(2014) does not include referanced drawings 2 through 6. <br />Please provide all referanced information for review. <br />19. The potential impacts too powerline structures were not included in the proposed Exhibit 2.05.6 - <br />E4. In order to determine compliance with 2.05.6(6), Please provide the Division with the <br />supplimental subsidence survey addressing the potential impacts to the Powerline structures <br />identified. <br />20. Proposed Page 8 of Exhibit 2.05.6 -E4 states that an anticipated worst case effect to the <br />Twentymile Sandstone is damage to raptor habitat and nest sites. Proposed monitoring and <br />mitigation is proposed to be covering existing nest sites during periods of potential cliff failure. <br />Pleae provide information to the Division from the appropriate governmental agency concuring <br />with the proposed mitigation plan concerning raptor habitat. <br />-'c��a <br />1313 Sherman Street, Room 215, Denver, CO 80203 P 303.866.3567 <br />I <br />1876 <br />