My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2001-10-25_REPORT - M1980244
DRMS
>
Day Forward
>
Report
>
Minerals
>
M1980244
>
2001-10-25_REPORT - M1980244
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2021 1:56:35 PM
Creation date
2/25/2014 5:46:19 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
REPORT
Doc Date
10/25/2001
Doc Name
Final Report QA Oct 2001for "External Pond" Doc 1 of 10
From
CC&V
To
DRMS
Media Type
D
Archive
No
Tags
DRMS Re-OCR
Description:
Signifies Re-OCR Process Performed
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
228
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
October 2001 -16- 003-2182.004 <br /> 4.1.3 AtterbergLimits <br /> imits <br /> Golder performed Atterberg limit testing of all fill materials. All fill materials, with the <br /> exception of Soil Liner Fill were non-plastic. The testing frequency(approximately one test per <br /> 3000 cubic yards for Soil Liner Fill) exceeded the minimum specified testing frequency. The <br /> Soil Liner Fill, Leak Detection Fill, Pipe Bedding Fill, Structural Fill, and Base Course samples <br /> tested met project specifications for Atterberg limits. The plasticity index of the two CQA Soil <br /> Liner Fill samples was 29, which met the project specification of plasticity index greater than or <br /> equal to 10. Atterberg limit test results are presented in Appendix G-1 and summarized in <br /> Tables 4-8. <br /> 4.1.4 Proctor Compaction Tests <br /> Golder performed standard Proctor compaction tests of Soil Liner Fill and testable Structural <br /> Fill in order to compare in-place densities and moisture contents with laboratory derived values <br /> of maximum dry density and optimum moisture content. On Structural Fill samples where the <br /> amount of material larger than 3/4-inch particle size was less than or equal to that allowed by <br /> the ASTM D698 test method, a Proctor test was performed on samples of the Structural Fill <br /> used for site grading. <br /> Golder performed four CQA standard Proctor compaction tests of Structural Fill. The testing <br /> frequency (approximately one test per 14,400 cubic yards) exceeded the minimum specified <br /> testing frequency of one test per 50,000 cubic yards. The Structural Fill compaction test results <br /> are presented in Appendix G-2 and summarized in Table 4. CQC Proctor tests were not <br /> included in the Proctor testing frequency. <br /> Golder performed two CQA standard Proctor compaction tests of Soil Liner Fill. The testing <br /> frequency (approximately one test per 3,000 cubic yards) exceeded the minimum specified <br /> testing frequency of one test per 5,000 cubic yards. The Soil Liner Fill compaction test results <br /> I\oo\2isx\ExrERNAL POND RPrFWALDOC Golder Associates <br />