My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WSPC05545
CWCB
>
Water Supply Protection
>
Backfile
>
18000-18999
>
WSPC05545
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2010 12:01:41 PM
Creation date
10/9/2006 5:17:41 AM
Metadata
Fields
Template:
Water Supply Protection
File Number
8220.106.A.1.c
Description
Colorado River Water Projects - Animas La Plata - Description - Construction - Durango Pump Station
State
CO
Basin
Colorado Mainstem
Water Division
5
Date
10/7/2002
Author
DOI-BOR
Title
Durango Pumping Plant - Stage I - Project Specifications - Volume III-B
Water Supply Pro - Doc Type
Report/Study
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
164
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />OJ2LJ2 <br /> <br />DuranRo PumoinR Plant - StaRe 1 <br /> <br />,~ <br />I"~ <br /> <br />PART 1 <br /> <br />SECTION 03210 - REINFORCING STEEL <br /> <br />GENERAL <br /> <br />1.01 MEASUREMENT AND PAYMENT <br /> <br />A. Reinforcing Steel: <br />1. Measurement: Number of pounds of reinforcing steel installed, including splices, <br />2. Payment: Unit price per pound offered in the schedule. <br /> <br />1.02 REFERENCES <br /> <br />A. American Concrete Institute (ACI) <br /> <br />1. <br /> <br />ACI3l5R-94 <br /> <br />Manual of Engineering and Placing Drawings for <br />Reinforced Concrete Structures <br /> <br />B. American Society for Testing and Materials (ASTM) <br /> <br />1. ASTM A 6l5-96a Deformed and Plain Billet-Steel Bars for Concrete <br />Reinforcement <br /> <br />2. <br /> <br />ASTM A 6l7-96a <br /> <br />Axle-Steel Deformed and Plain Bars for Concrete <br />Reinforcement <br /> <br />J ~ 1.03 SUBMITTALS <br /> <br />A. Pre-submittal meeting with Government. <br /> <br />1. Prior to beginning detailing, meet with the Government to discuss format, content, <br />and detail of reinforcement detail drawings, <br /> <br />B, Submit the following for approval in accordance with Section 01330 - Submittals: <br /> <br />C, Reinforcement detail drawings <br /> <br />1, Submit reinforcement detail drawings after receipt of approved concrete <br />placement drawings, The Government will require 25 calendar days' for review of <br />reinforcement detail drawings, and this review time will apply to each separate <br />submittal or resubmittal. <br /> <br />Do not place reinforcement in any structure until reinforcement drawings <br />describing the reinforcement are approved by the COR. <br /> <br />Include bar-placing drawings, bar-bending diagrams, total weight of bars on each <br />drawing, and bar lists. <br /> <br />Prepare from design drawings, <br /> <br />Prepare in accordance with ACI 3l5R. <br /> <br />Show details necessary for checking bars during placement and establishing <br />payment quantities. <br /> <br />'~ <br /> <br />2. <br /> <br />3, <br /> <br />4, <br />5, <br />6. <br /> <br />Reinforcing Steel <br />03210-1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.