Animas -La Plata Project <br />Feb 13, 2013 Draft Transfer Inspection Report <br />TRANSFER ISSUE <br />STIPULATION <br />Butterfly valves condition <br />See Section 4 above. (M1E, M2E, M117, M2F, D5, and MPA <br />Pump condition <br />through MPF) <br />Pump condition <br />See Section 5 above. <br />Background: The capability of, and actual control that the Auxiliary Control Panel has of <br />the filling, draining, pumping, and COD valves needs to be confirmed. The Association <br />requests that the pumps are configured such that (manually or through SCADA) both Unit <br />1 and Unit 2 pumps can operate simultaneously, with one pumping to COD and one <br />pumping to Lake Nighthorse or both pumping to Lake Nighthorse. The need and logic of <br />pump and plant shutdowns that are tied to both 14 cfs pumps requires documentation. <br />The ACP logic associated with the isolation, filling, and guard valves requires <br />documentation for completion of the SOP. <br />7. 28 CFS Pumping Units 3 and 4, Piping, and Valves <br />There are two horizontal centrifugal split -case pumps, nominally rated at 28 cfs. They are <br />driven by two 2,500 hp electric motors. <br />The following are located between the suction manifold and discharge manifold: <br />• Motor - operated, AWWA Class 150B, 24" suction butterfly valves — (M3D, M413) <br />• Air valve <br />• Motor - operated, ANSI class 300, 24" discharge butterfly valves — (M3E, M4E) <br />• Hydraulically dampened 24" check valves <br />• Manually- operated, ANSI class 300, 24" guard butterfly valves — (M3F, M4F) <br />• Connection to 72" discharge manifold <br />TRANSFER ISSUE <br />STIPULATION <br />Butterfly valves condition <br />See Section 4 above. (M3E, M4E, M3F, M4F) <br />Pump condition <br />See Section 5 above. <br />8. 56 CFS Pumping Units 5 - 8, Piping, and Valves <br />There are four horizontal centrifugal split -case pumps, nominally rated at 56 cfs. They are <br />driven by four 5,000 hp electric motors. <br />The following are located between the suction manifold and discharge manifold: <br />• Motor - operated, AWWA Class 150B 36" suction butterfly valves — (M5D - M8D) <br />• Air Valve <br />• Motor - operated, ANSI class 300 36" discharge butterfly valves — (M5E - M8E) <br />• Hydraulically dampened 36" check valve <br />• Manually- operated, ANSI Class 300 36" guard butterfly valves — (M5F - M8F) <br />• Connection to 72" discharge manifold <br />TRANSFER ISSUE I STIPULATION <br />Butterfly valves condition I See Section 4 above. (M5E through MBE, M5F through M8F) <br />Transferred Works Inspection 19 Animas -La Plata Project <br />
The URL can be used to link to this page
Your browser does not support the video tag.