Animas -La Plata Project <br />Feb 13, 2013 Draft Transfer Inspection Report <br />TRANSFER ISSUE <br />STIPULATION <br />There is no protection <br />Reclamation will ensure that all motor operated discharge and <br />between the service bay <br />Reclamation will install a roughly 2' net around the perimeter of <br />and the unit bay from <br />the opening to catch any falling objects. <br />falling objects <br />Reclamation will provide vent caps for all gear boxes. <br />The Uninterruptable Power <br />Reclamation will test the system and ensure complete <br />Supply (UPS) device DSE has <br />functionality. <br />not been tested <br />The door lock cylinders are <br />missing from the service <br />Reclamation will provide the appropriate door lock cylinders. <br />bay workroom <br />There is no code call system <br />Reclamation will install a suitable code call system in the plant. <br />installed at the plant <br />Background: Shrinkage cracks in the concrete deck were providing a water pathway to <br />the control room and the bus gallery. The entire deck was caulked from the interior, <br />pressure grouted from the exterior, and overlaid with an epoxy grout to seal the surface. <br />Minor control room seepage exists, but Reclamation anticipates that repairs to asphalt <br />paved areas and concrete joints, referenced in the transfer issues above, will remedy this <br />situation. Reclamation will continue to monitor control room seepage. <br />3. Suction (Intake) Manifold <br />In the pumping plant structure, the 84" diameter steel pipe manifolds into the individual <br />pump intake lines that feed Units 1 through 8. One combination air valve is located on the <br />suction manifold between the connections for pumping units 3 and 4. <br />4. Butterfly Valves - General <br />Butterfly valves are individually identified in the sections below, but all exhibit similar <br />problems. <br />Background. All butterfly valves, with the exception of the suction butterfly valves, have <br />difficulty operating. At the request of Reclamation, Flo - Controls, Inc., has evaluated the <br />situation and provided recommendations for mitigating the problem. Mitigation is <br />currently in progress. The agreed upon valve and valve operator modifications is jointly <br />being coordinated between Flo- Controls, Inc., Reclamation, Weeminuche Construction <br />Authority, and the Association <br />TRANSFER ISSUE <br />STIPULATION <br />Reclamation will ensure that all motor operated discharge and <br />Butterfly valves exhibit <br />guard valves, and all manually operated guard valves are capable <br />excessive difficulty opening <br />of being operated as designed. <br />All operator gear boxes <br />Reclamation will provide vent caps for all gear boxes. <br />need vent caps <br />5. Pumping Units - General <br />The eight main pumping units are horizontal, split -case, centrifugal pumps directly <br />connected to a horizontal shaft and synchronous motor. They consist of four large pumps <br />Transferred Works Inspection 17 Animas -La Plata Project <br />