Laserfiche WebLink
Animas -La Plata Project <br />Feb 13, 2013 Draft Transfer Inspection Report <br />Approximately 160 feet south of the spherical air chamber is located a flow meter structure <br />for the Ridges Basin Inlet Conduit. The structure is approximately 14' wide, 18' long, and 20' <br />tall, and installed below the ground surface. <br />At the southeast corner of the pumping plant is located the flow measurement structure <br />and 9' diameter cylindrical air chamber for the City of Durango's water supply pipeline. <br />2. Durango Pumping Plant Structure and Site <br />The pumping plant is an indoor -type structure with a cast -in -place reinforced concrete <br />substructure and superstructure. The roof system consists of a structural steel truss and <br />metal standing seam roof. The roof over the unit bay extends 17 feet above the service yard <br />elevation. The superstructure over the service bay extends 40 feet above the service yard <br />elevation. The plant is approximately 233' long and 89' wide. <br />TRANSFER ISSUE <br />STIPULATION <br />Reclamation will continue to monitor previous efforts (grouting <br />and sealing entire deck) for water seepage into these areas. <br />Water leaks into control <br />Should any unacceptable seeps occur, Reclamation will mitigate <br />room and motor control <br />the problem. Reclamation will also ensure that the leaking <br />gallery <br />electrical conduit in the control room is repaired. Reclamation <br />will also paint the control room ceiling where repairs were made. <br />Property boundary <br />Reclamation will install additional fencing with appropriate signs, <br />delineation and posting is <br />pending final operational footprint designation. <br />not complete <br />Curb stops are damaged <br />Reclamation will replace damaged parking blocks (curb stops) <br />beyond repair <br />with yellow solid plastic parking blocks. <br />Asphalt has deteriorated <br />Reclamation will sealcoat all asphalt paved areas and repair <br />and gaps exist adjacent to <br />asphalt and subgrade, including sealing the open concrete to <br />concrete drainages <br />asphalt joints. <br />There is excessive erosion <br />Reclamation will work with the Association to repair the erosion <br />on the slope above the <br />damage, and install suitable preventative measures for future <br />retaining walls <br />storm events. <br />Crane and elevator <br />inspection and certification <br />Reclamation will ensure that all appropriate inspection and <br />documentation has not <br />certification procedures are performed, and provide all <br />been provided to the <br />documentation to the Association. <br />Association <br />Piping on south unit bay <br />Reclamation will supply all materials necessary for the <br />wall interferes with crane <br />Association to re -align the piping. <br />operations <br />The catwalk mounting <br />brackets on the north unit <br />Reclamation will install column supports for the catwalk. <br />bay wall are severely <br />corroded <br />Exterior light housings have <br />Reclamation will provide the materials for the Association to <br />stained the building exterior <br />touch up the exterior as needed. <br />Transferred Works Inspection 16 Animas -La Plata Project <br />