My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
C150050 contract docs
CWCB
>
Loan Projects
>
DayForward
>
1001-2000
>
C150050 contract docs
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2010 8:24:18 AM
Creation date
7/2/2010 12:22:05 PM
Metadata
Fields
Template:
Loan Projects
Contract/PO #
C150050
Contractor Name
Mesa County Board of County Commissioners
Contract Type
Grant
Loan Projects - Doc Type
Contract Documents
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
� • <br />scale. All drawings shall be numbered sequentially in a manner approved by <br />COUNTY so that match lines follow each other from one drawing to the next. <br />2.B.7. ENGINEER shall clearlv describe in the preliminary design report (see <br />Section ?.B.8. the contents and improvements of the recommended plan shown <br />on each draw Priority of improvements shall be discussed. Reaches of <br />improvements or isolated improvements that can be implemented independently <br />shall be described. <br />2.B.8. At the completion of the above work, ENGINEER shall prepare a <br />preliminary design written report which will state the decision reached by <br />COUNTY and LOCAL SPONSORS as a result of the work on draina.ge and <br />indicate any changes that may have occurred to that decision during the conduct <br />of preliminary design. This report will contain copies of all major graphical <br />studies, plans, etc., used in arriving at the final recommendation; summary of <br />hydrologic study and findings, similar to drainage report; typical calculations; <br />charts; special studies (including scouring, maintenance, soils, etc.); preliminary <br />design drawings; maintenance requirements; and all other items described in <br />Section 2.B. of this Agreement. In addition, this report will contain reference to <br />all calculations and materials used by ENGINEER to consummate his study and <br />a legal opinion of the selected plan (to be provided by COUNT'I�. The <br />information in the report will be sequential, orderly and directed to COtJNTY <br />and LOCAL SPONSORS. The report will consist of one plastic comb bound <br />volum�. The first part of the report shall contain a narrative description and the <br />second part will contain the plan and profile drawings reduced to 11" s 17" vvith <br />the facing sheet containing a description of drainage and other problems and the <br />recommended improvements and conditions shown on the facing drawing and a <br />detailed, component by component cost estimate of the improvements shown. <br />The number of dra.ft copies of the final report, as specified under Section 3' <br />below, will be submitted to COUNTY for review purposes. ENGINEER will <br />print final copies after review and acceptance by COiJNTY and LOC.AL <br />SPONSORS. COUNTY reserves the right to reject the printing if it results in a <br />loss of legibility in background, contours line work, lettering, or of esact scale <br />at �0 percent reduction. The number of copies of the completed preliminary <br />design report, as specified under Section 3 below, shall be furnished to <br />COUNTY. <br />
The URL can be used to link to this page
Your browser does not support the video tag.