A/ternative No. 4- Rep/ace the Upstream Out/et Gates and Repafr the <br />Out/et Conduits <br />This alternative consists of replacing the upstream outlet gates and repairing the steel lined section of <br />the outlet conduits. In this alternative the reservoir would be drained down to facilitate construction at <br />the gates and replacement of the 44 inch steel lined section of outlet conduit. The existing gates and <br />operators would be removed. Two new slide gates would be installed. The installation requires a <br />connection to the outlet conduits, so the upstream most segments of the existing conduits would be <br />removed and replaced as part of the installation. This work would include replacing the segment of <br />conduit where the leak currently exists through the existing fitting. New hydraulic operators would be <br />installed along the upstream face of the dam. Operators would be encased in concrete to minimize the <br />potential for ice damage. A new gate shack will be installed at the crest of the dam to house operations. <br />Power and a SCADA system will be run to the gate shack and the system will be configured to facilitate <br />both local operations at Milton Reservoir and remote operations from FRICO's office in Brighton. <br />While the reservoir is drained, FRICO will also be ab~e to remove the existing 44 inch steel lined sections <br />of the outlet works and replace them with new steel lining. This will be possible as a drained reservoir <br />offers less hydrostatic pressure on the outlet works, provides a condition where work within the outlet <br />can be completed in the dry, and removal of the existing outlet gates will provide a source of fresh air for <br />working within the conduit. <br />This alternative would meet all of FRICO's objectives by replacing the updated headworks and allowing <br />upstream operations of the reservoir. It would also repairs the aged steel lined conduit section and <br />provide FRICO with the ability to operate flows through the system is a safe environment. <br />Our opinion for the probable cost for Alternative No. 4 project is $630,192.80 as shown below on Table <br />3. <br />14 <br />