Laserfiche WebLink
ADZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334 -5493 <br />Star Mine Operations LLC <br />L12888 -05 WG346694 Silica, total <br />WG346994 Chloride <br />WG346890 Cyanide, total <br />WG346903 Cyanide, WAD <br />WG346650 Fluoride <br />WG346196 Phosphorus, ortho dissolved <br />M200.7 ICP <br />SM4500CI -E <br />SM4500CI -E <br />M335.4 - Colonmetnc w/ <br />distillation <br />SM4500 -CN I- Colonmetricw/ <br />distillation <br />SM450OF -C <br />M365.1 - Automated Ascorbic <br />Add <br />M365.1 - Automated Ascorbic <br />Add <br />M365.1 - Automated Ascorbic <br />Add <br />WG346565 Residue, Non - Filterable (TSS) @105C SM2540D <br />WG346911 Sulfate D516- 02- Turbidimetric <br />REPAD.15.06.05.01 <br />ACZ Project ID: L12888 <br />ZS Digestion procedures have the potential to trigger silica <br />polymerization and precipitation, leading to low biased <br />results. Silica chemistry is complex and polymerization <br />kinetics are unpredictable. Dissolved and/or acid soluble <br />silica analyses may provide more accurate measurements. <br />Mt Matrix spike recovery was high, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />M2 Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />ZU Analysis date/time preceeds fitter date/time. A portion of <br />sample was filtered and analyzed prior to the creation of a <br />Filter workgroup. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />M3 The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />Page 40 of 45 <br />