Laserfiche WebLink
ACZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334 -5493 <br />Star Mine Operations LLC ACZ Project ID: L12887 <br />L12887 -02 WG346694 Iron, total M200.7 ICP <br />WG346886 Molybdenum, dissolved M200.81CP -MS <br />WG346994 <br />Chloride <br />SM4500CI -E <br />WG346890 <br />Cyanide, total <br />M335.4 - Colorimetric w/ <br />distillation <br />WG346875 <br />Cyanide, WAD <br />SM4500 -CN I- Colorimetricw/ <br />distillation <br />WG346650 <br />Fluoride <br />SM450OF -C <br />WG346196 Phosphorus, ortho dissolved M365.1 - Automated Ascorbic <br />Add <br />M365.1 - Automated Ascorbic <br />Add <br />M365.1 - Automated Ascorbic <br />Add <br />WG346442 Residue, Filterable (TDS) (eti3180C SM2540C <br />WG346439 Residue, Non - Filterable (TSS) @105C SM2540D <br />L12887 -03 WG346886 <br />WG346994 <br />WG346890 <br />WG346875 <br />WG346650 <br />WG346196 <br />Molybdenum, dissolved <br />Chloride <br />Cyanide, total <br />Cyanide, WAD <br />Fluoride <br />Phosphorus, ortho dissolved <br />M200.8 ICP-MS <br />SM4500CI -E <br />M335.4 - Colorimetric w/ <br />distillation <br />SM4500 -CN I- Cdorimetricw/ <br />distillation <br />SM450OF -C <br />M365.1 -Automated Ascorbic <br />Add <br />M365.1 - Automated Ascorbic <br />Add <br />M365.1 - Automated Ascorbic <br />Acid <br />WG346442 Residue, Filterable (TDS) @180C SM2540C <br />WG346439 Residue, Nan - Filterable (TSS) @105C SM2540D <br />REPAD.15.06.05.01 <br />M3 The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />M3 The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />M1 Matrix spike recovery was high, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />M2 Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />ZU Analysis dateltime preceeds filter date/time. A portion of <br />sample was filtered and analyzed prior to the creation of a <br />Filter workgroup. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />M3 The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />M1 Matrix spike recovery was high, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />M2 Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />ZU Analysis date/time preceeds filter date/time. A portion of <br />sample was filtered and analyzed prior to the creation of a <br />Filter workgroup. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />Page 24 of 29 <br />